Location and positioning
Introduction
Congratulations on purchasing your smoke alarm. You can easily install multiple alarms
throughout the property on escape routes, on each story, in corridors and in closed
rooms to give warning of re. The smoke alarm can be wirelessly connected to a supple-
mentary Visit receiver in order to provide an additional warning.
NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION
Smoke detection. Where required by applicable laws, codes, or standards for the
specied occupancy, approved single- and multiple-station smoke alarms shall be
installed as follows:
1 In all sleeping rooms. Exception: Smoke alarms shall not be required in sleeping rooms
in existing one- and two-family dwelling units.
2 Outside of each separate sleeping area, in immediate vicinity of the sleeping rooms.
3 On each level of the dwelling unit, including basements Exception: In existing one- and
two-family dwelling units, approved smoke alarms powered by batteries are permitted.
Are more smoke alarms desirable?
The required number of smoke alarms might not provide reliable early warning protec-
tion for those areas separated by a door from the areas protected by the required smoke
alarms. For this reason, it is recommended that the householder consider the use of
additional smoke alarms for those areas for increased protection.
87
The additional areas include the basement, bedrooms, dining room, furnace room, utility
room, and hallways not protected by the required smoke alarms
The installation of smoke alarms in kitchens, attics (nished or unnished), or garages
is not normally recommended, as these locations occasionally experience conditions
that can result in improper operation.
The equipment should be installed using wiring methods in accordance with the Na-
tional Fire Protection Association’s Standard 72, Chapter 11. (National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269).
IMPORTANT!
Specic requirements for smoke alarm installation vary from state to state and from
region to region. Check with your local re department for current requirements in
your area.
SMOKE ALARM TRANSMITTER, BE1281
Sucient smoke must enter your smoke alarm before it will respond. Your smoke alarm
needs to be within 6.4 meters (21ft) of the re to respond quickly. Your smoke alarms
also need to be in positions where they can be heard throughout the property, so they
can wake you and your family in time for everyone to escape. A single smoke alarm
will give some protection if it is properly installed, but most homes will require two or
more to ensure that a reliable early warning is given. For recommended protection you
should put individual smoke alarms in all rooms where re is most likely to break out
(apart from the kitchen and bathroom).