User's Manual

General instructions
Read and retain this booklet for as long as the product is being used. It contains vital
information on the operation and installation of your smoke alarm. The booklet should
be regarded as part of the product. If you are just installing the unit, the booklet must
be given to the householder. The booklet is to be given to any subsequent user.
Please note
This BE1281 Smoke alarm transmitter, hereafter referred to as the smoke alarm, is
equipped with a BE9171 radio module from Bellman & Symfon, hereafter referred to
as the RF module. The RF module transmits signals to supplementary Visit receivers
from Bellman & Symfon. The supplementary Visit receivers are hereafter referred to
as the Visit receivers.
The Visit receivers are not included in the smoke alarm package. The complete func-
tionality is explained in the products’ user manual.
Indication summary
Please note
The indication summaries for the Visit receivers are
found in the products’ user manuals.
Smoke alarm
Horn/sounder
Smoke alarm
Red LED
Radio module
Green LED
Normal operation
Power up O 1 blink Blinking for 2 s
Standby O 1 blink every 45 s 1 blink every 45 s
Sensing re Full sound Rapid blinking
(every 0.5 s)
Rapid blinking
Fault mode
Low battery 1 beep every 45 s 1 blink every 45 s O
Faulty smoke sensor 1 beep every 45 s O O
Test mode
Test smoke alarm
(press button)
Ramps to full sound Rapid blinking
(every 0.5 s)
Rapid blinking
Silence smoke alarm
(press button)
O 1 blink every 8 s for
10 min
1 blink every 8 s for
10 min
3 4
Green LED Red LED