User's Manual
17
Technical information
Power supply
Mains power: 7.5 V DC / 1500 mA.
This product is also designed for IT power distribution
system with phase to phase voltage of up to 230V. The
socket-outlet shall be installed near the equipment and
shall be easily accessible.
Battery back-up: 4x1.2V Lexel 600mAh/900mAh
Please dispose used batteries at municipal collecting points or dispense them to local stores
free of charge.
Additional information
Programming pin (16): For service personal only (Output: 3.3V/max. 150mA)
CAUTION: Do not use, unit will be damaged when used.
Activation
Radio: Bellman Visit system
Via analogue
telephone network: 26 - 120 V RMS, 15 - 100 Hz.
Self-Maintenance
Information: Test this device once a month
WARNING: The telephone port of the Flasher Receiver must be connected using 26
AWG or greater telecommunications wire.
Output signals
Output signals Built-in ash light signal >10 Candela
Warning! Flashes can cause epileptic attacks.
Vibrator power 2.0 – 4.0 VDC (max. 500mA)
For indoor use only Temperature range 0°C – 40°C
Dimensions Ø x H: 70 x 140 mm
Weight: 320 g
Colour: White
Optional accessories (sold seperately)
Wall Mount Bracket BE9075
Bellman Bed-shaker BE1271
Telephone Flex BE9105
Adapter plug for the appropriate country
EN