User's Manual
13
When successfully paired, the corresponding LED will light up to indicate the smoke
alarm hardware ID sequence in BE1444 memory. (Sequence indication: please refer to
the Information above. )
Attach the corresponding label (provided with each smoke alarm transmitter) on the smoke
alarm transmitter unit so you can easily identify it later.
Indication of smoke alarm ID
sequence in BE1444
Sequence
smoke alarm 1
smoke alarm 2
smoke alarm 3
smoke alarm 4
smoke alarm 5
smoke alarm 6
smoke alarm 7
smoke alarm 8
LED lights up LED ashes
BE1444 can maximum store 8 smoke alarm hardware ID. When manually paring the 9th
smoke alarm to BE1444, the four LED orange, green yellow and red will blink
at the same time for 30 seconds, to indicate the hardware ID storage failure which means
the smoke alarm supervision function is not available.