Using battery backup
The Visit Smart hub is equipped with a battery backup that ensures full
functionality during power loss for at least 48 hours.
Replacing batteries
Unplug the mains power and open the front cover. Replace the old bat-
teries with new ones, see the instructions in the battery compartment for
correct positioning.
Important!
Use 1.5 V AA, LR6 lithium or alkaline batteries only.
NEVER mix lithium batteries with alkaline batteries
as the batteries and unit can overheat. Always keep batter-
ies out of reach of children. Dispose of batteries according
to your local environmental laws and guidelines.
Technical information
Power supply DC 5V
Power consumption Active < 50 mA, Idle position < 6 mA
Backup battery 2 x 1.5 V AA (LR6) lithium or alkaline batteries
Activation Via test buttons or a Visit monitor
Monitor frequency 315/433.92/868.3 MHz depending on region
Monitor coverage 33 – 77 yd. (30 – 70 m) depending on radio
frequency. Coverage is reduced by walls, large
objects and other radio transmitters.
Bluetooth® frequency 2400 – 2483.5 MHz
Bluetooth® coverage Up to 33 yd. (30 m). Coverage is reduced by thick
walls and large objects.
Compatible monitors BE1411 Door transmitter, BE1431 Telephone
transmitter, BE1491 Room monitor, BE1240/1420
Push button transmitter and BE1281/1480
Smoke alarm transmitter