Technical data
INSTALLATION
13.302
Clearances & dimensions
The room should have good light and
ventilation but be free from draughts.
The work top should be at least 600mm
deep, & 30mm thick to enable the cutout
to be made to the dimensions shown
below.
A minimum distance of 40mm should be
maintained between the hob and rear wall
/ combustible surface.
A minimum distance of 40mm should be
maintained between the hob and any side
walls / combustible surface.
We recommend ceramic tiling for the rear
wall directly behind the hob.
No shelf or overhang of combustible ma-
terial should be closer than 650mm above
the hob.
Extractor or cooker hoods should only be
ttedabovethehobinaccordancewith
the manufacturer’s instructions.
Nocombustiblematerialsorammable
liquids should be stored below the hob.
Sufcientlengthofcableshouldbeal-
lowed so the hob can be removed for
servicing, but make sure it is routed away
from the underside of the hob & does not
get trapped during installation.
Important: Ensure that you route all
electrical cables and exible tub-
ing well clear of any adjacent heat
source - e.g. oven / grill.
600 hob - 600mm
700 hob - 700mm
40mm
40mm
worktop
420
mm
wall unit
This area must
be kept clear
of combustible
materials
650mm
above level of
pan supports
53mm min
side wall
rear wall
555mm
490
mm
cutout
60cm hob - 53mm min
70cm hob - 103mm min
wall unit