Technical data

INSTALLATION
13.302
Installation above a unit with a
drawer or door
The base of the appliance must be pro-
tected from damage e.g. drawers may
only be installed providing a partition
panelisttedtotherequireddimensions
underneath the appliance.
Worktop
25mm
Oven
Hob
INSTALLATION ABOVE AN OVEN
Worktop
25mm
Partician
Hob
Partition
INSTALLATION ABOVE A UNIT WITH
A DRAWER OR DOOR
Ventilation Requirements
The room containing the appliance should
have an air supply in accordance with
BS5440:Part2
•Allroomsrequireawindowthatopens,
or equivalent, and some rooms will require
a permanent vent as well.
•Forroomvolumesupto5m
3
an air vent
of 100cm
2
is required.
•Iftheroomhasadoorthatopensdi-
rectly to the outside, or the room exceeds
10m
3
NO AIR VENT is required.
•Forroomvolumesbetween5m
3
and
10m
3
an air vent of 50cm
2
is required.
•Ifthereareotherfuelburningappli-
ancesinthesameroom,BS5440:Part
2:(orequivalent)shouldbeconsultedto
determine the air vent requirements.
•Thisappliancemustnotbeinstalledina
bed sitting room of less than 20m
3
or in a
bathroom or shower room.
•Windowsandpermanentventsshould
therefore not be blocked or removed with-
outrstconsultingacompetentengineer.
LP Gas only - Do not install this appliance
in a room below ground level. This does
not preclude installation into rooms which
are basements with respect to one side of
the building but open to ground level on
the opposite side.
For installation into environments other
than domestic dwellings, e.g. caravans,
boats and similar - refer to the relevant
standards on ventilation and gas supply.
Failure to install appliances correctly
is dangerous & could lead to pros-
ecution.