Service manual
19
TECHNICAL SPECIFICATIONS
NOMINAL RESISTANCES AT 20oC
*5,//(/(0(17,11(5 :
287(5
5+29(1/2:(5(/(0(17 :
5+29(1723(/(0(17:
5+29(1)$1(/(0(17 :
/+29(1)$1(/(0(17:
6/2:&22.(5(/(0(17:
0$,129(167,5)$1
&22/,1*)$1 N
THERMAL CUT-OUTS
TOP....................... L120°C
REAR................... L150°C
FAN RUN-ON..... F60°C