Service manual
Conversion Instructions
This conversion kit is for use on the following appliances:
Dual Fuel - all sizes.
This conversion kit is to be used to convert the above appliances from:
UK Appliance Nat Gas to LP - Natural Gas G20 @ 20mbar to LPG G30/31 @
29/37mbar
UK Appliance LP to Nat Gas - LPG G30/31 @ 29/37mbar to Natural Gas G20 @
20mbar
UK to German LPG G30/G31 @ 50 mbar
UK to Australian NG @ 1.0kPa
UK to Australian ULPG @2.75kPa
Before beginning conversion, ensure that the Gas and Electricity supplies have been
turned off. The full conversion must be completed - i.e. you must change the injectors
and the by-pass pins.
Important: The conversion procedure must be carried out by a suitably qualified person
i.e. Corgi registered. After conversion all affected parts must be checked for gas sound-
ness.
Injectors & Bypass Screws
UK / Europe NG
Hotplate burner Auxiliary ( Small) Semi Rapid
(Medium)
Rapid (Large) Wok
Inner Outer
Injector 77 104 129 63 121
UK / Europe LP (Excluding Germany)
Hotplate burner Auxiliary ( Small) Semi Rapid
(Medium)
Rapid (Large) Wok
Inner Outer
Injector 50 70 87 35 87
Germay LP
Hotplate burner Auxiliary ( Small) Semi Rapid
(Medium)
Rapid (Large) Wok
Inner Outer
Injector 46 61 79 35 77
Australian NG
Hotplate burner Auxiliary ( Small) Semi Rapid
(Medium)
Rapid (Large) Wok
Inner Outer
Injector 82 118 142 72 138
Bypass 63 63 77
Australian ULPG
Hotplate burner Auxiliary ( Small) Semi Rapid
(Medium)
Rapid (Large) Wok
Inner Outer
Injector 50 70 87 35 87
Bypass 32 39 45 80
43