Service manual

Technical Data - Notes
Type of gas:
Please see data badge your for specified gas type.
Never attempt to convert an appliance - unless the data badge states that you can.
Burner Aeration: Fixed
Pressure setting: Natural Gas - 1.0 kPa
Propane - 2.75 kPa
Electrical supply: 220 - 240V ~ 50Hz
Countries of destination:
Injectors used (hotplate)
To convert the hotplate burners
a) Remove the pan supports
b) Remove the burner caps and burner heads
c) Unscrew the existing injectors from the hotplate burner bowls
d) Replace with the injectors supplied in the conversion kit as detailed in the table.
Note: when converting the wok burner, it is necessary to replace the two injectors, the
inner and outer. The outer injector is visible on removal of the cover plate.
To convert the gas tap bypass screws
a) Remove the hotplate control knobs springs and bezels
b) Using a small flat bladed screwdriver, each bypass screw can be accessed
via the hole in the inner fascia panel
c) NG to LP - Turn each bypass screw fully clockwise until it stops.
Do not over tighten
d) Refit the control bezels, springs and control knobs.
e) Add the label stating “ONLY FOR USE WITH PROPANE GAS” next to the gas inlet.
Size Natural
Gas
LP gas
Small 82 50
Medium 118 70
Large 142 87
Wok 138 & 72 87 & 35
AUS
32