Service manual

Installing Your Cooker
We recommend that this appliance is connected by a com-
petent person, who is a member of a recognised
“Competent Persons Scheme” and who will comply with
local regulations.
The appliance must be installed using a multi-pole control
unit of 13 Ampere minimum capacity with 3mm minimum
contact separation at all poles, which must remain acces-
sible after installation.
Ensure that you route all mains electrical cables well clear
of any adjacent heat source, such as an oven or grill.
Where a fixed connection is used, a device allowing the
appliance to be isolated on all poles from the mains sup-
ply with a contact opening width of at least 3mm must
be provided.
After connection to the electricity please check that all
electrical parts are working.
The maximum power rating is specified in the Technical
Data section of this handbook, and also on the Data
Badge on the appliance.
Connecting the electricity supply
Warning: This appliance must be earthed!
Access to the mains terminal is gained by removing the
terminal block cover at the rear of the appliance - use
a pozi N
o
2 screw driver for this.
Connection should be made with a minimum 1.5mm
2
twin and earth cable.
First strip the wires. Then push the cable through the
cable clamping the terminal block cover.
Connect the cable to the terminal block and tighten the
cable clamp screw - see diagram.
Replace the cover.
Sufficient cable should be used to allow the cooker to
be pulled out, but must hang clear of
the floor so it does not become twisted
or trapped when the cooker is pushed
back.