Technical data

Data badge
Lower part of front frame and rear of
appliance.
Type of gas
This cooker is factory set for use on
Natural Gas only, as specified on the
appliance data badge.
Gas category
Natural Gas - I2H
Pressure setting
Natural Gas G20 @ 20mbar
Appliance class
Class 3, built in oven and grill
Ignition
Mains operated re-ignition generator
Electrical supply
220 - 240V ~ 50Hz
Grill
Nominal Rate Qn 1.8kW
Oven
Bray type burner, sheet steel body,
stainless steel flame strip
Nominal Rate Qn 2.5kW
Injector 115
Spark gap 3 - 4mm
Thermostat bypass 50
Oven injector - If the injector is
removed or replaced for any reason, it
is mandatory to apply Hylomar PL32
or Plasticol X10 sparingly to the thread
prior to (re) fitting.
Maximum heat input
Qn 2.5kW
Countries of destination
GB - Great Britain
29