User guide
INSTALLATION
INSTALLATION
21
13.500
the unit, we recommend that a gap of
at least 80mm is made by shortening
the shelf.
4. When installing the appliance below
a work top, there must be a minimum
ventilation area of 60cm
2
below the
appliance, either through the plinth or
through the kick board, as indicated
on the previous page. There must be a
minimum 5mm gap between the front
top edge of the oven and the under-
side of the work top.
5. A 12mm deep gap should be cut into the plinth adjacent to the front bot-
tom edge of the appliance, to improve airow.
Important
:
Do not modify the outer panels of this appliance in any way.
Ensure that you route all mains electrical cables and exible tubing well clear of
any adjacent heat source, such as an oven, grill or hob.
Installing the appliance under a work top
Where the appliance is installed under a work top, with a hob installed above it,
the installation instructions for the hob must be read in conjunction with these
instructions.
Important
:
If a hob is tted above your appliance always ensure it is well sealed
to prevent water damage to your new appliance.
STEP 2 & 3 CONNECT TO THE ELECTRICITY
SUPPLY
We recommend that the appliance is con-
nected by a competent person who is a
member of a “Competent Person Scheme”
& who will comply with the I.E.E. & Local
regulations.
Important
: Ensure that you route all mains
electrical cables well clear of any adjacent
heat source, such as an oven or grill.
Warning! This appliance must be
earthed.
For 60cm BI appliance:
1. Where a xed connection is used, a
device allowing the appliance to be iso-
lated on all poles from the mains supply
80mm MIN TO
BACK OF
SUPPORT
SHELF
WALL
5mm MIN
CLEARANCE
5mm MIN
CLEARANCE
FLOOR
CABINET BASE
WORK TOP
SUPPORT SHELF
AIRFLOW
AIRFLOW
FRONT OF
COOKER
AIRFLOW
Door release tabs
Cable clamp
Cable clamp screw
1
2
3
Live
Neutral
Earth
4
5
BROWN / L
BLUE / N
GREEN/YELLOW / PE
230V.....240V
60cm Terminal Block
Connection Schematic
1
2
3
4
5