Installation guide
CHECKING BURNER PRESSURE
9
Burner pressure of the appliance can
be checked at the gas re g u l a t o r
(Natural Gas) or middle rear burner
(Semi Rapid) on the appliance hob.
To check the burner pressure of the
appliance at the middle rear hob burn-
er, the adaptor (illustrated) will be
required.
Remove the burner jet from the middle
rear burner (Semi Rapid) and screw in
the adaptor.
Connect the test equipment, and ignite
the rear left burner (Rapid) and oper-
ate at its maximum gas rate.
Pressure should be be as stated on the
data badge (adjust the pressure if
required)
Removed the adaptor and replace the
jet in the middle rear burner (Semi
Rapid).
Bypass Screw adjustment
The low rate setting of the individual
gas burners are preset for Natural
Gas and should not require adjust-
ment.
However, if adjustment is required
then the bypass screw, situated on the
gas tap and located through the aper-
ture in the control panel, can be
adjusted with the aid of a thin bladed
flat ended screw driver as follows:
Clockwise adjustment to lower the
flame.
Anticlockwise to increase the flame.
A torch may assist in this operation.
The bypass screw adjustment