Specifications

21
Cable requirements
For optimum clarity of speech it is strongly recommended that this system
is installed using twisted-pair telephone cable (eg type CW1308). Use one
of the pairs for the R & O connection between the speech unit and the
telephone.
Installation Procedure
Connect all items by following wiring diagram 4. It is strongly
recommended that a single telephone be connected at a time and fully
tested before proceeding to the next.
Speech adjustment
The model 51 speech unit has two pots at the rear for adjustment of
speech levels as follows:
Volume A: Speech level at the Entrance Panel
Volume B: Speech level at the Telephone
If feedback is experienced (a howl or whistle) turn both controls to 'off' and
then slowly adjust each up in turn until a satisfactory level of speech is
attained.
Troubleshooting
No speech/ Insufficient speech: Initially establish correct operation of the
Speech Unit by disconnecting all telephones and connecting a known
working telephone with a short length of cable (R O T only); Reconnect the
telephones one at a time until the fault re-appears. Note: speech will be
impaired if one or more telephones are left off the hook.
CS109 Complete Systems
The CS109-N systems include all of the components necessary for a
single-door Coded Access and Door Entry Telephone System:-
1 x Model 108Plus Coded Access Controller in a lockable steel cabinet.
1 x CP109-N Anodised AluminiumEntrance Panel with integral keypad
and surface mounting back-box and including a model 51 speech
unit.
N x Model 500D Door Entry Telephones
1 x Model 340 Power Supply Unit.
1 x Model 203 Lock Release.