Specifications

15
Testing the controller with factory settings
Before proceeding with this test ensure that the lock release and alarm device (if used)
are working correctly by following the above test procedures.
Program the access channel to be tested to factory settings by following the instructions
under the heading ‘programming the factory settings ’(page 7).
! Type in code 1 (1 2 3 4 5) - this should operate the lock release for 3 seconds.
! Remove any connections to the ‘TIME’ terminals and type code 2 (6 7 8 9 0) -
nothing should happen. Now short-circuit the ‘TIME’ terminals together with a
short piece of wire and retype code 2 (6 7 8 9 0) - the lock release should
operate for 3 seconds.
! Reprogram code 1 to another value by following the instructions under the
heading ‘Programming new access codes’ (page 8); check that the new code
operates the lock release and that the old one does not.
If any of the above tests should fail then follow the keypad test procedure.