Specifications

10
Programming The Key Limit (Function 8)
The key Limit determines the number of keys that may be pressed in attempting to
enter the correct access code before activating the Alarm. Choose a value which is a
multiple of the number of digits in the code e.g for a 4 digit code set the key limit to 12
to allow 3 attempts. To disable this feature program the key limit to 0.
To program a key limit use function 8:
L Move slide switch to ‘PGM’
L Type : 8(( <0-99> # e.g. 8( 12 # (limit = 12 keys)
L Observe red and green LEDs turn on briefly
L Move slide switch to ‘RUN’
Programming a Code Entry Time Limit (Function 9)
This limits the time allowed for entry of the correct access code. Timing starts from
pressing the first key and if the remainder of the access code has not been entered
before this time limit elapses the alarm is activated. The code entry time limit is
programmable from 1-99 seconds or this feature is disabled by selecting a time of ‘0'
.
To program a code entry time limit use function 9:
L Move slide switch to ‘PGM’
L Type : 9(( <0-99> # e.g. 9( 20 # (limit of 20 secs)
L Observe red and green LEDs turn on briefly
L Move slide switch to ‘RUN’
NOTE: when the code entry time limit function is disabled the 108 PLUS will
automatically engage a timed memory clear function. If no key has been pressed for 10
seconds all previous entries will be cleared ; this is important to ensure that the system
cannot be left primed by a partially entered correct access code.