Unit installation
719S 2 Door Switching Unit
4
TEST BUTTON
There are two Test buttons on the PCB marked 'TEST 1' and 'TEST 2'. Pressing the
appropriate button will force entrance 1 or 2 into an active state for a fixed period
(speech active time). Telephone models with privacy must also be buzzed to enable
speech. This feature is provided to assist in fault diagnosis during installation and
commissioning.
LED STATUS INDICATORS
To assist in testing and fault diagnosis there are 4 LED Indicators on the 719S PCB
which can be interpreted as follows:-
LED 1 (GREEN) - Speech Active Door 1
LED 2 (RED) - Lock Release Active Door 1
LED 3 (GREEN) - Speech Active Door 2
LED 4 (RED) - Lock Release Active Door 2