Manual

INSTRUCTION MANUAL
HS-240
REVISION B
Dura-Stat
®
Thermostatic Module
For Warren Webster Thermostatic Traps
Model 02H and 502
Before using product, read and understand instructions.
Save these instructions for future reference.
All work must be performed by qualified personnel trained in the proper application,
installation, and maintenance of steam systems in accordance with all applicable codes
and ordinances.
To prevent serious burns, wear heat resistant gloves when opening and closing
steam valves, or handling hot equipment.
To prevent serious burns, the internal pressure of the trap must be 0 psi (0 bar) before
servicing.
Failure to follow this caution could cause personal injury.
W
ARNING
CAUTION
!
CAUTION
INSTALLATION
A
C
B
1.a Remove the trap cover (A) from the body (B).
b. Unscrew the thermostatic element (C) from
the cover (A).
c. Discard the old thermostatic element (C).
E
B
2a. Using a 7/8” (22mm) socket wrench,
remove and discard the seat (E) from
the trap body (B).
b. Discard the old seat (E).

Summary of content (2 pages)