Brochure

26
100% factory tested - guarantees operation
Five year limited warranty - the best in the business
Replaceable, standard “ice cube” type relays allow up to 10 amps,
1/3 HP per individual zone
Selectable priority for domestic hot water
30 minute built-in priority timer helps prevent house freeze up - no additional
plug-in cards required
Automatically resetable fuse protects controller from overload - eliminates
“no heat” call backs due to blown fuse
Powerful transformers operate up to six zones
LED diagnostic lights installed internal to the box cover keeps the trouble
shooting in the hands of the authorized heating professionals
Can be used with “tankless coil” or “cold start” applications
Specifications
Specifications
RELAYS ZONETROL
Switching Relays
for Zoning with Valves
Features
Model
Number
Part
Number
Zones
Priority
Feature
Transformer
Output
at 24 Volts
Relay
Switching
Action
Each End
Switch Contact
Rating
Dimension
W x H x D (inches)
Approx.
Shpg. Wt.
(lbs.)
ZTV-4 109407 4 yes 40 VA DPDT
5A, 1/8 HP
@ 120VAC
9-1/4 x 7-1/4 x 2-3/4 4.6
ZTV-6 109408 6 yes 75 VA DPDT 11-3/8 x7-1/4 x 3-3/4 6.9
RELAYS ZONETROL II Switching Relays
with Reset Option for Zoning with Pumps
Description
Bell & Gossett’s ZoneTrol II is a ready-to-install controller for hydronic
circulators in residential and light commercial applications. All ZoneTrol II
controllers are UL and cUL listed and feature multi-function LEDs that are
visible without removing the cover for easy start-up and troubleshooting.
All units are compatible with analog and digital 24 VAC thermostats,
including “power stealing” designs. The multi-zone controllers feature an
advanced microprocessor design that provides domestic hot water (DHW)
priority & timer, pump exercise and a post purge timer without the need
for add-on circuit boards or modules.
Four and six zone controllers are field expandable for up to 18 pumps.
* fits 4 and 6 zone controllers only one required for each slave controller.
Model
Number
Part
Number
Zones
Combined Load
(max.) @ 120 VAC
Dimensions W x L x D
Inches (mm)
Weight
Lbs (kg)
Z-1 109424 15 amps 6.5 x 5 x 3 (165 x 127 x 76) 2.6 (1.18)
Z-2 109425 2 20 amps 6.5 x 5 x 3 (165 x 127 x 76) 3 (1.36)
Z-3 109426 3 20 amps 6.5 x 5 x 3 (165 x 127 x 76) 3.1 (1.4)
Z-4 109427 4 20 amps 13.5 x 8.25 x 3.25 (343 x 210 x 83) 7.3 (3.3)
Z-6 109430
6
13.5 x 8.25 x 3.25 (343 x 210 x 83)
7.5 (3.4)
ZC-11* 109454
Communication cable for connection of multiple controllers
0.1 (0.05)
20 amps
Standard Features (multiple zone controllers only)
Priority: Enables DHW zone to have priority over heating zones for limited period of time. User adjustable settings include OFF (disables priority
functionality), 30 minutes and 60 minutes.
Post Purge Timer: Circulator(s) will continue to run for 90 seconds after thermostat opens and allows additional extraction of BTUs from high
mass boilers. User adjustable settings are OFF and ON.
Exercise: Runs each circulator for 10 seconds after each 72 hours of inactivity. User adjustable settings are ON and OFF.
Expandability: 4 and 6 zone controllers can easily be connected via a ZC-11 cable to accommodate systems consisting of up to 18 circulators.
Five-year Warranty
The next generation of zone controllers
from Bell & Gossett brings 21st century
technology to residential controls.