Automatic Timer Kit
Model TC-1
Aquastat
Models: AQS-1/2, AQS-3/4
DESCRIPTION
TC-1 AUTOMATIC TIMER KIT -
To increase the overall efficiency of a
hot water recirculation system, the TC-
1 timer control kit can be
installed for use on any B&G NBF/NRF/SSF/PL and most 3-
piece
circulators. The TC-
1 timer control is programmable to turn the
circulator ON and OFF automatically at preset times. This permits the
user to have the pump circulate hot water only during those times
when high usage can be expected throughout the day.
AQS-1/2 and AQS-3/4 AQUASTAT -
are designed to thermostatically
turn any B&G NBF/NRF/SSF circulator ON and OFF. The AQS-
1/2 or
AQS-3/4 will switch the pump OFF at 120ºF (48.9ºC) and ON at 100º
F
(37.8º
C). The aquastats are available in separate models that will
sense the temperature for either 1/2" or 3/4" copper pipe.
AUTOMATIC TIMER KIT and AQUASTAT COMBINATION -
The
automatic timer and aquastat kits can be used in combination. When
they are used together, the pump will only circulate water when the
ON time conditions are met and when water temperature is low
enough to cause the aquastat to switch ON.
OPERATIONAL LIMITS
TC-1 AUTOMATIC TIMER KIT:
Power Supply: 115/120 VAC, 60 HZ, 1Ø
Minimum Switch Interval: 15 minutes
Run Modes: ON (continuous run), OFF (at all times),
TIMER (run at programmed intervals)
Maximum Switch Current: 16 amps
AQS-1/2, AQS-3/4 AQUASTATS
Thermostatic Switch Modes: OFF (open) at 120°F (48.9°C) and ON
(closed) at 100°F (37.8°C) operation of the aquastat is dependent on
ambient settings. In setting where there is excessive heat loss or in
installations where heat from the boiler or other components can affect
the aquastat, the actual on and off temperatures may vary.
Thermostatic Element: Bimetal, senses surface temperature of outside
diameter of pipe.
Pipe Size: AQS-
1/2 clips onto 1/2" copper pipe or 3/8" steel pipe (OD
of pipe 5/8"). AQS-
3/4 clips onto 3/4" copper pipe or 1/2" steel pipe
(OD of pipe 7/8").
Mounting: May be installed to sense temperature at the suction or
discharge pipe of the pump.
CONSTRUCTION MATERIALS
TC-1 AUTOMATIC TIMER KIT:
Timer Body: Noryl Plastic
AQS-1/2, AQS-3/4 AQUASTATS:
Thermostat Covering: Epoxy (Environmentally Sealed)
Pipe Clip: Stainless Steel
Sensing Element: Bimetal
Wire Leads: Insulated 18" (457mm) #18 AWG
APPROX. SHIPPING WEIGHT
TC-1: 11oz. (.31Kg)
AQS-1/2: 5oz. (.14Kg)
AQS-3/4: 5oz. (.14Kg)
SCHEDULE
MODEL
NUMBER
PART
NUMBER
SIZE
INCHES
VOLTAGE RATING
60 HZ 1Ø TAGGING INFORMATION QUANTITY
TC-1 113210 − 115-120
AQS-1/2 113223 1/2 115-120
AQS-3/4 113224 3/4 115-120