Residential Gateway (RG) Battery Backup BU3DC000-12V User Manual
Table of Contents Page Introduction..................................................................................................... 3 Safety Information..................................................................................... 3 System Requirements ............................................................................... 3 Package Contents .................................................................................... 4 Recycling ...................................................
Introduction Thank you for purchasing the Residential Gateway (RG) Battery Backup. Natural and man-made power disturbances can disrupt the power supplied to your home electronics. These power problems can disrupt the normal operation of important electrical equipment and related services. Battery Backups provide an uninterruptible power supply (UPS) to keep critical systems up and running in the event of a power loss.
Introduction Package Contents You should have received the following: 1 – RG Battery Backup unit (12V sealed lead battery included) Recycling UNIT CONTAINS SEALED LEAD BATTERY. BATTERY SHOULD BE RECYCLED. Belkin International, Inc., advocates sound environmental management of used batteries. For battery-replacement and recycling information, please call us at 866-539-5791, or visit our website at www. belkin.com/gatewaybattery.
Product Layout and Function Controls and Status Indicators Shown below are the controls and indicator lights on the RG Battery Backup. 1 Power on/off Power on/off switch is located on the back panel. Use this switch to turn the RG Battery Backup on/ off. The unit will not supply power to the AT&T U-verseSM Residential Gateway when power switch is in OFF position. 1 2 Status Indicators Three LED status lights are located on the front panel. The status lights indicate specific conditions of the device.
Residential Gateway (RG) Battery Backup Belkin Tech Support US: 866-539-5791 UK: 0845 607 77 87 Australia: 1800 235 546 New Zealand: 0800 235 546 Singapore: 800 616 1790 Europe: www.belkin.com/support Belkin International, Inc. 501 West Walnut Street Los Angeles, CA 90220, USA 310-898-1100 310-898-1111 fax Belkin Ltd. Express Business Park, Shipton Way Rushden, NN10 6GL, United Kingdom +44 (0) 1933 35 2000 +44 (0) 1933 31 2000 fax Belkin B.V.
Product Layout and Function Audible and Visual Alarms The RG Battery Backup alarms to indicate certain events. Front-Panel Label Visual Indicator Audible Alarm Description ON A/C Green LED lights None The RG Battery Backup is operating on A/C. Testing Battery Green LED flashes None The RG Battery Backup is conducting a self-test. This automatic procedure is normal and will occur when the unit is switched on, and periodically thereafter. This procedure will last approximately 5 minutes.
Installation NOTE: Before installation, please inspect the RG Battery Backup. Make sure that nothing inside the package is damaged. The RG Battery Backup must be installed near the Residential Gateway and be easily accessible. STEP 1: Connect to AC Utility Power Make sure that the power switch on the RG Battery Backup is in the OFF position. Plug the AC cord on the RG Battery Backup into a wall outlet.
Operation • Turning off the RG Battery Backup Turn switch to OFF position. The “ON A/C” LED light should turn off. • To Silence Audible Alarm Turn mute switch to ON (down) position. • To Conduct a Self-Test Use the self-test to verify both the operation of the RG Battery Backup and the condition of the battery. Turn the mute switch ON then OFF, then ON and OFF again within five seconds. During the self-test, the RG Battery Backup operates in backup mode.
Wall-Mounting Instructions (Optional) NOTE: Required hardware not included. Refer to the wall-mount instructions for required tools and materials. STEP 1: Position the template on the wall where you want to mount the RG Battery Backup and tape in place. STEP 2: Make a mark on the wall in the 2 screw locations indicated on the template. Remove the template from the wall. STEP 3: Use a drill to drill holes where you made the mark on the wall. If you drill into a wall stud, proceed to Step 5.
Battery-Replacement Procedure The RG Battery Backup is designed with an easy-access battery door. Replacement of the battery requires removing the battery door on the rear of the device. No tools are needed. STEP 1: Turn off power switch. Disconnect the RG Battery Backup from power and any connected devices. Remove the battery door on the rear of the RG Battery Backup by pressing the tab on the top of the battery door and pulling outward.
Technical Specifications Technical Specifications: Input Voltage Range 0 to 150VAC Input Frequency 50/60Hz Nominal Output Voltage – On A/C Mode 13.7VDC Nominal Output Voltage – On Battery Mode 12VDC Max Power 30W Cold-Start Functionality Included Output Transfer < 1ns Surge Protection Included Alarms Visual and Audible Battery (@ 25 degrees C): Type/Rating 12V/7.2Ah Battery Low-Alarm Level 11.0V +/- 0.5V Discharge Prevention 10.5V +/- 0.5V Overcharge Protection >14.5V +/- 0.