G6/G7 Globe Valves with Dual Mount GK-X1 Actuators
Wiring Diagrams
BLK
Black
Negro
Noir
Preto
RED
Red
Rojo
Rouge
Vermelho
WHT
White
Blanco
Blanc
Branco
PNK
Pink
Rosado
Rosa
Cor-de ros
ORG
Orange
Anaranjado
Orange
Alaranjado
BLU
Blue
Azul
Bleu
Azul
BRN
Brown
Marron
Brun
Marrom
Electronic Fail-Safe Actuator with -3 and -SR
2 3
24 VAC Transformer
Blk (1) Common
Red (2) + Hot
Wht (3) +
Line
Volts
18
Y input
1
Pnk (4)
18
A
B
Function
100%
Max
a
b
Blk (1) Common
Red (2) + Hot
Wht (3)
Y Input,
2 to 10V
Org (5)
U Output, 2 to 10V
24 VAC Transformer
5
7
Control Signal
(+)
VDC/mA
(–)
Feedbac
k Signal
(+)
2 to 10 VDC
(–)
500
Line
Volts
3
18
On/Off Floating Point VDC / 4 to 20 mA
2
100 to 240 VAC
Blu (1) Common
Brn (2) + Hot
Wht (3) + Input
N L1
H L2
A
Line
Hot
Function
100%
Max
a
a
2
100 to 240 VAC
Blu (1) Common
Brn (2) + Hot
Wht (3) + Input
N L1
H L2
A
Line
Hot
Function
100%
Max
a
b
A
B
Blk (1) Common
Red (2) + Hot
Wht (3) Y
Input, 2 to 10 V
Org (5) U Output 2 to 10 V
Master
Slave
24 VAC Transformer
Line
Volts
Control Signal
2 to 10 VDC or
4 to 20 mA
500
1/4 watt
(–)
(+)
Blk (1) Common
Red (2) + Hot
Wht (3) Y
Input, 2 to 10 V
Org (5) U
18
18
3
On/Off Floating Point VDC/ 4 to 20 mA (Master Slave)
Blk (1) Common
Red
(2) + Hot
Wht
(3) Y
1
Input
Pnk
(4) Y
2
Input
ComHot
Controller
Line
Volts
10
24 VAC Transformer
5
18
18
Blk (1) Common
Red
(2) + Hot
Wht
(3) Y
1
Input
Pnk
(4) Y
2
Input
ComHot
Controller
Line
Volts
24 VAC Transformer
Org (5) U Output
18
10
Blk (1) Common
Red
(2) + Hot
Wht
(3) Y
1
Input
Pnk
(4) Y
2
Input
ComHot
Controller
Line
Volts
24 VAC Transformer
Line
Volts
24 VAC Transformer
Triac Sink Triac Source Triac Sink with Separate Transformer
Electronic Fail-Safe Actuator with MFT
18
Blk (1) Common
Red
(2)
Hot
Wht
(3) Y Input
Org
(5)
U Output 2 to 10V
Line
Volts
24 VAC Transformer
2 to 10 VDC
Feedback Signal
(+)
(–)
3
Function
100%
Max
a
Line
Volts
(–)
(+)
24 VAC Transformer
Blk (1) – Common
Red (2) + Hot
Wht (3) Y
1
Input
Org (5) U Output 2 to 10V
CCW
CW
AB
18
CCW
CW
AB
Direction of rotation switch
A
B
2
9
8
10
12
Feedback Signal
2 to 10 VDC
18
18
Notes:
On/Off Floating Point
7
Blk (1) Common
Red
(2) + Hot
Wht
(3) Y
1
Input, 2 to 10V
Org (5) U Output, 2 to 10V
(–)
(+)
Line
Volts
24 VAC Transformer
500
1/4 watt
3 18
Control Signal
VDC/mA
18
500
Blk (1) Co
mmon
Red (2) + Hot
Org
(5)
Wht (3) Y
1
Input, 2 to 10V
(–)
(+)
Line
Volts
24 VAC Transformer (AC Only)
7
B
C
A
1/4 watt
VDC/mA
Control Signal
Functions
0%
50%
100%
Control mode acc. to Y
Min*
Mid*
Max*
Normal**
* Default selectable 0-100%. See Configuration Data Sheet.
** Customizable. See Configuration Data Sheet.
abc
VDC / 4 to 20 mA Override Control Min, Mid, Max Positions
Meets cULus requirements without the need of an
electrical ground connection.
A
Actuators with appliance cables are numbered.
2
Actuators may be connected in parallel. Power
consumption and input impedance must be observed.
3
Actuators may also be powered by 24 VDC.
5
Only connect common to neg. (-) leg of control circuits.
7
A 500 Ω resistor converts the 4 to 20 mA control signal
to 2 to 10 VDC.
8
Control signal may be pulsed from either the Hot
(Source) or Common (Sink) 24 VAC line.
9
Contact closures A & B also can be triacs. A & B should
both be closed for the triac source and open for triac
sink.
10
For triac sink the Common connection from the actuator
must be connected to the Hot connection of the
controller. Position feedback cannot be used with a triac
sink controller. The actuator internal common reference
is not compatible.
12
IN4004 or IN4007 diode. (IN4007 supplied, Belimo Part
number 40155).
18
Actuators with plenum rated cable do not have numbers
on wires; use color codes instead.