Characterized Control Valves™ (CCV) Features and Benefits EQUAL PERCENTAGE VALVE CHARACTERISTIC In order to ensure good stability of control, it is essential for a control valve to have an equal percentage characteristic. This type of characteristic produces a linear variation in thermal output according to the amount of opening of the valve (also known as the system characteristic). Under normal testing conditions a conventional ball valve exhibits an S-shaped characteristic.
Feature / Benefits Characterized Control Valves™ (CCV) COORDINATED MOTORIZED OPERATION The optimum functionality of the Belimo CCV is assured by properly coordinating its actuation with MFT. Specially developed rotary actuators provide the necessary precision for modulating, floatingpoint, and on/off methods of control.
Sizing/Selection Characterized Control Valves™ (CCV) O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc. 2-Way Valve Flow Rate for Water Applications (Gallons Per Minute, GPM) Cv Maximum Rating Inches DN mm 2-Way CCV Pressure Drop Across the Valve 1 psi 2 psi 3 psi 4 psi 5 psi 6 psi 7 psi 8 psi 9 psi 10 psi 0.3 0.46 0.8 1.2 1.9 3 4.7 7.4 10 14 4.7 7.4 10 14 24 7.
Sizing/Selection Characterized Control Valves™ (CCV) 3-Way Valve Flow Rate for Water Applications (Gallons Per Minute, GPM) Inches DN mm 3-Way CCV Pressure Drop Across the Valve 1 psi 2 psi 3 psi 4 psi 5 psi 6 psi 7 psi 8 psi 9 psi 10 psi 0.3 0.46 0.8 1.2 1.9 3 4.7 10 14 4.7 7.4 14 24 7.
Set-up and Wiring Instructions Characterized Control Valves™ (CCV) SET-UP 2-WAY VALVE SPECIFY UPON ORDERING Power to pin 2 will drive valve CCW. Power to pin 3 will drive valve CW. TR24-3-T US TR24-3 US Stays in Last Position NON-SPRING RETURN On/Off or Floating Point Actuators TR24-SR-T US TR24-SR US Note Fail Position SPRING RETURN Power to pin 2 will drive valve CCW. Power to pin 3 will drive valve CW. NC: Closed A to AB, will open as voltage increases.
Flow, Operation and Installation Characterized Control Valves™ (CCV) FLOW PATTERNS 2-way Characterized Control Valves™ (Belimo B2 Series) (Belimo B6 Series) Flow Direction Two-way valves should be installed with the disc upstream. Upstream A Downstream AB 3-way Characterized Control Valves™ MIXING (Belimo B3 Series) DIVERTING The A-port must be piped to the coil to maintain proper control. INCORRECT PIPING The A-port must be piped to the coil to maintain proper control.
Nomenclature Characterized Control Valve™ (CCV) B2 09 B LRX 24 -MFT Valve B2 = 2-way B3 = 3-way B6 = 2-way Flanged Valve Size 07-80 = ½”-3” Control Actuator Type Power Supply Blank = On/Off, Floating Trim Material Non-Spring Return 24 = 24 VAC/DC -3 = Floating Point 120 = 120 VAC* B = Brass TR… 230 = 230 VAC Blank = Stainless LRB… Steel Trim LRX… ARB… ARX… LRQ... NRQ... Spring Return TFR… LF… AFR... Electronic Fail-Safe GK...
This Page Intentionally Left Blank 8 O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
B2 Series, 2-Way, Characterized Control Valve Chrome Plated Brass Ball and Brass Stem Application This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable flow.
B3 Series, 3-Way, Characterized Control Valve Chrome Plated Brass Ball and Brass Stem Application This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable or constant flow.
B2 Series, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem Application Tefzel® is a registered trademark of DuPont Dimensions Valve Body B207-B211 B212-B216 B217-B221 B222-B225 B229-B230 B231-B232 B238-B240 B248-B250 B251-B254 B261-B265 B277-B280 Valve Nominal Size Inches DN [mm] ½” 15 ½” 15 ¾” 20 1” 25 1¼” 32 1¼” 32 40 1½” 2” 50 2” 50 2½” 65 3” 80 800-543-9038 USA Dimensions (Inches [mm]) A B 2.41” [61.1] 1.39” [35.2] 2.38” [60.4] 1.78” [45.2] 2.73” [69.3] 1.87” [47.4] 3.09” [78.
B3 Series, Three Way, Characterized Control Valve Stainless Steel Ball and Stem Application This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable or constant flow.
B6 Series, Two Way, Characterized Control Valve Stainless Steel Ball and Stem Application This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable or constant flow. O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
Characterized Control Valve Product Range Overview B2.., B3.., 2-way, 3-way, Stainless Steel Ball and Stem Type Suitable Actuators 3-way NPT Inches 0.3 ½ 15 B207(B) B307(B) 0.46 ½ 15 B208(B) B308(B) 0.8 ½ 15 B209(B) B309(B) 1.2 ½ 15 B210(B) B310(B) 1.9 ½ 15 B211(B) B311(B) 3 ½ 15 B212(B) B312(B) 4.7 ½ 15 B213(B) B313(B) 7.4 ½ 15 B214(B) 10 ½ 15 B215(B) 14 ½ 15 B216(B)* B316(B)* 4.7 ¾ 20 B217(B) B317(B) 7.
Characterized Control Valve Product Range Overview B6..
TR24-3 Actuators, On-Off, Floating Point 2.50 [63.5] 3.25 [82.6] D06 D069 Dimensions with 2-Way Valve 2.82 [71.6] B A Models Input impedance Angle of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing rating Agency listing† on/off, floating point 24 VAC 50/60 Hz 19.2…28.8 VAC 1W 1VA (class 2 power source) screw terminals accessible after removal of small cover (3 ft, 10 ft, 16 ft cables optional) 0.
TR24-3 Actuators, On-Off, Floating Point Wiring Diagrams 3 The common connection from the actuator must be connected to the Hot connection of the controller. Actuators with plenum rated cable do not have numbers on wires; use color codes instead. 4 The actuator Hot must be connected to the control board Hot. 2 W187 NOTE: E TR24-3(-T) US cannot be wired in parallel with themselves or any other actuator.
TR24-SR Actuators, Proportional 2.50 [63.5] 3.25 [82.6] D069 Dimensions with 2-Way Valve 2.82 [71.6] B A Models TR24-SR-T US with 3 ft plenum rated cable TR24-SR-T US with 10 ft plenum rated cable TR24-SR-T US with 16 ft plenum rated cable Input impedance Angle of rotation Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing rating Agency listing† Noise level Quality standard Dimensions (Inches [mm]) A B 2.41” [61.
TR24-SR Actuators, Proportional 2 W190 Wiring Diagrams Actuators with color coded wires are optional. Wire numbers are provided for reference. CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC.
LR...
LR...24-3 Actuators, On/Off, Floating Point Wiring Diagrams 2 CAUTION Equipment damage! 3 Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators are provided with color coded wires. Wire numbers are provided for reference. 4 Actuators may also be powered by 24 VDC. On/Off control Meets cULus or UL and CSA requirements without the need of an electrical ground connection.
LR...
LR...24-SR Actuators, Proportional Wiring Diagrams 2 CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (–) leg of control circuits. 2 to 10 VDC control Meets cULus or UL and CSA requirements without the need of an electrical ground connection.
LR...
LR...120-3 Actuators, On/Off, Floating Point Wiring Diagrams 2 CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Meets cULus or UL and CSA requirements without the need of an electrical ground connection. On/Off WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components.
LR...
LR...120-SR Actuators, Proportional Wiring Diagrams 2 19 CAUTION Equipment damage! N L1 1 Neutral Actuators may be connected in parallel. Power consumption and input impedance must be observed. H L2 2 Hot + 6 6 Only connect common to neg. (–) leg of control circuits. 7 A 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC. 1 15 LRB(X) can be supplied with both 120 VAC and 230 VAC. 19 All 120 VAC and 230 VAC actuators use appliance rated cables.
LR...
LR...24-MFT Actuators, Multi-Function Technology Wiring Diagrams 2 3 4 6 8 9 CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators may also be powered by 24 VDC. Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. Contact closures A & B also can be triacs.
LRX24-PC Actuators, 0 to 20V Phasecut, Proportional D149-2 Dimensions with 2-Way Valve Technical Data Power supply Power consumption Transformer sizing Electrical connection Overload protection Operating range Y Feedback output U Input impedance Angle of rotation Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Quality standard 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% running 2 W hold
LRX24-PC Actuators, 0 to 20V Phasecut, Proportional Wiring Diagrams 1 1 2 3 24 VAC Transformer Line Volts Provide overload protection and disconnect as required. CAUTION Equipment damage! Blk (1) Common – Red (2) Hot + 3 Pnk (6) Y Input, 0 to 20V phasecut Actuators may be connected in parallel. Power consumption and input impedance must be observed. Control Signal (–) 0 to 20 V Phasecut (+) Actuators may also be powered by 24 VDC.
LRX24-MFT95 Actuators, 0 to 135 Ω, Proportional D149-2 Dimensions with 2-Way Valve Technical Data Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 2 W holding 1.
Wiring Diagrams Switch A Switch B W_new60408_5 LRX24-MFT95 Actuators, 0 to 135 Ω, Proportional Damper Position Damper Open Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire R. 21 Provide overload protection and disconnect as required. Line Blk (1) Common Volts 23 A Wht (3) W 135 7 Resistor value depends on the type of controller and the 24 4 number of actuators. No resistor is used for one actuator.
LRQ...
LRQ...24-1 Quick Running Actuators, On/Off Wiring Diagrams 1 Provide overload protection and disconnect as required. 3 Actuators may also be powered by 24 VDC. Meets cULus or UL and CSA requirements without the need of an electrical ground connection. LRQ...24-1 WARNING Live Electrical Components! O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
LRQ...
LRQ...24-MFT Quick Running Actuators, Multi-Function Technology 1 2 W399_08 Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 5 Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. W399_08 VDC/4-20 mA The ZG-R01 500 Ω resistor may be used.
NRQ...
NRQ...24-1 Quick Running Actuators, On/Off Wiring Diagrams 1 Provide overload protection and disconnect as required. 3 Actuators may also be powered by 24 VDC. Meets cULus or UL and CSA requirements without the need of an electrical ground connection. NRQ...24-1 WARNING Live Electrical Components! O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
NRQ...
NRQ...24-MFT Quick Running Actuators, Multi-Function Technology 1 2 W399_08 Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 5 Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. W399_08 VDC/4-20 mA The ZG-R01 500 Ω resistor may be used.
NRB24-3-T N4 NEMA 4X Actuators, On/Off, Floating Point NEMA 4 Diagram Dimensions with 2-Way Valve Models w/built in heater Power consumption Transformer sizing Electrical connection Overload protection Input impedance Angle of rotation Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing type Housing material Agency listings† Quality standard on/off, floating point 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% running 2.
NRB24-3-T N4 NEMA 4X Actuators, On/Off, Floating Point Wiring Diagrams 2 CAUTION Equipment damage! 3 Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators are provided with color coded wires. Wire numbers are provided for reference. 4 Actuators may also be powered by 24 VDC. On/Off control Meets cULus or UL and CSA requirements without the need of an electrical ground connection.
NRB24-SR-T N4 NEMA 4X Actuators, Proportional NEMA 4 Diagram Dimensions with 2-Way Valve Models w/built in heater Power consumption Transformer sizing Electrical connection Overload protection Input impedance Angle of rotation Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing type Housing material Agency listings† Quality standard 2 to 10 VDC, 4 to 20 mA 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% running 2.
NRB24-SR-T N4 NEMA 4X Actuators, Proportional CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (–) leg of control circuits. The ZG-R01 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel.
NRX24-MFT-T N4 NEMA 4X Actuators, Multi-Function Technology NEMA 4 Diagram Dimensions with 2-Way Valve Models w/built in heater Valve Body B207-B211 B212-B215 B217-B221 B222-B225 B229-B230 Technical Data Control Dimensions (Inches [mm]) A B 2.41” [61.1] 1.39” [35.2] 2.38” [60.4] 1.78” [45.2] 2.73” [69.3] 1.87” [47.4] 3.09” [78.4] 1.87” [47.4] 3.72” [94.6] 1.87” [47.
NRX24-MFT-T N4 NEMA 4X Actuators, Multi-Function Technology Wiring Diagrams 2 3 4 6 8 9 CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators may also be powered by 24 VDC. Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. Contact closures A & B also can be triacs.
AR...24-3 Actuators, On/Off, Floating Point D155 Dimensions with 2-Way Valve 3.46" [88] 8.5" [216] 2.49" [63.4] 3.3" [84] 1.35" [35] B A Valve Body B231-B232 B238-B240 B248-B250 B251-B254 B261-B265 B277-B280 Models w/built-in Aux. Switch Flexible Flexible w/built-in Aux. Switch Dimensions (Inches [mm]) A B 3.72” [94.6] 1.98” [50.4] 3.88” [98.5] 1.98” [50.4] 4.21” [107.0] 2.21” [56.2] 4.93” [125.2] 2.68” [68.0] 5.55” [140.9] 2.68” [68.0] 5.82” [147.9] 2.68” [68.
AR...24-3 Actuators, On/Off, Floating Point Wiring Diagrams Dimensions 3.46" [88] 8.5" [216] 2.49" [63.4] 3.3" [84] CAUTION Equipment damage! 2 Actuators may be connected in parallel. Power consumption and input impedance must be observed. For end position indication, interlock control, etc., ARB24-3-S incorporates one built-in auxiliary switches: 1 x SPDT, 3A (0.5A) @250 VAC, UL listed, adjustable 0° to 95°. 1.35" [35] A 3 C Actuators may also be powered by 24 VDC.
AR...24-SR Actuators, Proportional D152-2 Dimensions with 2-Way Valve Valve Body B231-B232 B238-B240 B248-B250 Models ARB24-SR ARX24-SR Valve Nominal Size Inches DN [mm] 1¼” 32 40 1½” 2” 50 Dimensions (Inches [mm]) A B 3.72” [94.6] 2.04” [51.9] 3.88” [98.5] 2.04” [51.9] 4.21” [107.0] 2.27” [57.
AR...24-SR Actuators, Proportional Wiring Diagrams 24 VAC Transformer 2 Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (–) leg of control circuits.
AR...
AR...120-3 Actuators, On/Off, Floating Point Wiring Diagrams Dimensions 3.46" [88] 8.5" [216] 2.49" [63.4] 3.3" [84] Provide overload protection and disconnect as required. 1 1.35" [35] CAUTION Equipment damage! 2 Actuators may be connected in parallel. Power consumption and input impedance must be observed. A C Meets cULus or UL and CSA requirements without the need of an electrical ground connection.
AR...120-SR Actuators D149-2B Dimensions with 2-Way Valve Valve Body B231-B232 B238-B240 B248-B250 Models ARB120-SR ARX120-SR Valve Nominal Size Inches DN [mm] 1¼” 32 40 1½” 2” 50 Dimensions (Inches [mm]) A B 3.72” [94.6] 2.04” [51.9] 3.88” [98.5] 2.04” [51.9] 4.21” [107.0] 2.27” [57.
AR...120-SR Actuators Wiring Diagrams 2 19 CAUTION Equipment damage! N L1 1 Neutral Actuators may be connected in parallel. Power consumption and input impedance must be observed. H L2 2 Hot + 6 6 Only connect common to neg. (–) leg of control circuits. 7 A 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC. 1 15 ARB(X) can be supplied with both 120 VAC and 230 VAC. 19 All 120 VAC and 230 VAC actuators use appliance rated cables.
AR...
AR...24-MFT Actuators, Multi-Function Technology AR_MFT_LGCCV Dimensions 3.46" [88] A C On/Off control B Valve Body Nominal Pipe Size B6250 2½" [65] B6300 3" [80] B6400 4" [100] Top Flange Design F05 Flange Diameter Face-to-Face Length A B Height C 7.50" [190.5] 5.50" [139.7] 8.10" [205.4] 8.00" [203.2] 6.60" [167.6] 8.40" [213.1] 9.00" [228.6] 8.30" [210.8] 9.30" [235.9] Floating Point O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
ARX24-PC Actuators, Phasecut D149-2A Dimensions with 2-Way Valve Technical Data Power supply Power consumption Transformer sizing Electrical connection Overload protection Operating range Y Feedback output U Input impedance Angle of rotation Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Quality standard 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% running 4 W holding 1.25 W 5.
ARX24-PC Actuators, Phasecut Wiring Diagrams 1 1 2 3 24 VAC Transformer Line Volts Provide overload protection and disconnect as required. CAUTION Equipment damage! Blk (1) Common – Red (2) Hot + 3 Pnk (6) Y Input, 0 to 20V phasecut Actuators may be connected in parallel. Power consumption and input impedance must be observed. Control Signal (–) 0 to 20 V Phasecut (+) Actuators may also be powered by 24 VDC.
ARX24-MFT95 Actuators, 0 to 135 Ω D149-2A Dimensions with 2-Way Valve Technical Data Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 4 W holding 1.25 W 6 VA (Class 2 power source) Transformer sizing Electrical connection ½” conduit connector 18 GA plenum rated cable 3 ft [1m], 10 ft [3m], 16 ft [5m] electronic throughout 0 to 95° rotation Overload protection Operating range WRB 0 to 135 Ω Honeywell Electronic Series 90, 0 to 135 Ω input Feedback output U 2 to 10 VDC, 0.
ARX24-MFT95 Actuators, 0 to 135 Ω Dimensions with 2-Way Flanged Valve Switch A Switch B Damper Position Damper Open D151_A 3.46" [88] Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire R.
ARB24-3-T N4 NEMA 4X Actuators, On/Off, Floating Point NEMA 4 Diagram_A Dimensions with 2-Way Valve Models w/built in heater Power consumption Transformer sizing Electrical connection Overload protection Input impedance Angle of rotation Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing type Housing material Agency listings† Quality standard on/off, floating point 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% running 2.
ARB24-3-T N4 NEMA 4X Actuators, On/Off, Floating Point Wiring Diagrams 2 24 VAC Transformer 2 3 4 4 Blk (1) Common – Line Volts CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. For end position indication, interlock control, etc., ARB24-3-S incorporates one built-in auxiliary switches: 1 x SPDT, 3A (0.5A) @250 VAC, UL listed, adjustable 0° to 95°.
ARB24-SR-T N4 NEMA 4X Actuators, Proportional NEMA 4 Diagram_A Dimensions with 2-Way Valve Models w/built in heater Power consumption Transformer sizing Electrical connection Overload protection Operating range Y Input impedance Angle of rotation Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing type Housing material Agency listings† Quality standard 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% running 2.5 W / heater 23 W holding 0.
ARB24-SR-T N4 NEMA 4X Actuators, Proportional Wiring Diagrams Wiring Diagrams with actuator types ..-3 2 CAUTION Equipment damage! N L L Actuators may be connected in parallel. Power consumption and input impedance must be observed. 1 2 3 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (–) leg of control circuits.
ARX24-MFT-T N4 NEMA 4X Actuators, Multi-Function Technology NEMA 4 Diagram_A Dimensions with 2-Way Valve Models w/built in heater Valve Body B231-B232 B238-B240 B248-B250 B251-B254 B261-B265 B277-B280 Technical Data Control Dimensions (Inches [mm]) A B 3.72” [94.6] 2.04” [51.9] 3.88” [98.5] 2.04” [51.9] 4.21” [107.0] 2.27” [57.7] 4.93” [125.2] 2.73” [69.5] 5.55” [140.9] 2.73” [69.5] 5.82” [147.9] 2.73” [69.
ARX24-MFT-T N4 NEMA 4X Actuators, Multi-Function Technology Wiring Diagrams 2 3 4 6 8 9 CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators may also be powered by 24 VDC. Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. Contact closures A & B also can be triacs.
GRB24-3, GRX24-3 Actuators, On/Off, Floating Point GR_LGCCV Dimensions 8.30” [210.8] 3.84” [97.
GRB24-3, GRX24-3 Actuators, On/Off, Floating Point W254_08 Wiring Diagrams 1 Provide overload protection and disconnect as required. 3 Actuators may also be powered by 24 VDC. Meets cULus requirements without the need of an electrical ground connection. WARNING G Live Electrical Components! On/Off control W255_08 During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components.
GRX24-MFT Actuators, Multi-Function Technology Dimensions 8.30” [210.8] 3.84” [97.
GRX24-MFT Actuators, Multi-Function Technology 2 3 4 5 8 9 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Actuators may also be powered by 24 VDC. Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible.
TFRB(X) Actuators, On/Off 3.05" [76.2] D09 94 Dimensions with 2-Way Valve 6.28" [159.55] 2.4 [6 2.93" [74.5] B Valve Body B207(B)-B211(B) B212(B)-B215(B) B217(B)-B221(B) Models TFRB(X)120 TFRB(X)120-S on/off Power consumption motor spring Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† TFRB(X)...-S Auxiliary switch 6.28" [159.55] 24VAC ± 20%, 50/60Hz 24VDC ± 10% (nominal) 100 to 240 VAC, 50/60 Hz (tolerance) 85 to 265 VAC, 50/60 Hz running 2.
TFRB(X) Actuators, On/Off Wiring Diagrams 24 VAC Transformer 1 Common 2 3 3 2 + Hot CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. TFX24 US 2 Actuators may also be powered by 24 VDC. 100 to 240 VAC Meets cULus or UL and CSA requirements without the need of an electrical ground connection.
TFRB(X)24-3 Actuators, Floating Point 3.05" [76.2] D09 94 Dimensions with 2-Way Valve 6.28" [159.55] 2.4 [6 2.93" [74.5] B Valve Body B207(B)-B211(B) B212(B)-B215(B) B217(B)-B221(B) Models TFRB(X)24-3 TFRB(X)24-3-S Valve Nominal Size Inches DN [mm] ½” 15 ½” 15 ¾” 20 Dimensions (Inches [mm]) A B 2.41” [61.1] 1.39” [35.2] 2.38” [60.4] 1.78” [45.2] 2.73” [69.3] 1.87” [47.4] w/built-in Aux. Switch Transformer sizing Electrical connection (-S models have 2 cables) TFRB(X)24-3...
TFRB(X)24-3 Actuators, Floating Point Wiring Diagrams 24 VAC Transformer 5 7 Blk (1) Common Red (2) a Wht (W3) ~ ~ b Or ~ e xx xx xx 4 Actuators may be connected in parallel. Power consumption and input impedance must be observed. The common connection from the actuator must be connected to the Hot connection of the controller.
TFRB(X)24-SR Actuators, Proportional 3.05" [76.2] D09 94 Dimensions with 2-Way Valve 6.28" [159.55] 2.4 [6 2.93" [74.5] B Valve Body B207(B)-B211(B) B212(B)-B215(B) B217(B)-B221(B) Models TFRB(X)24-SR TFRB(X)24-SR-S Valve Nominal Size Inches DN [mm] ½” 15 ½” 15 ¾” 20 Dimensions (Inches [mm]) A B 2.41” [61.1] 1.39” [35.2] 2.38” [60.4] 1.78” [45.2] 2.73” [69.3] 1.87” [47.4] w/built-in Aux.
TFRB(X)24-SR Actuators, Proportional Wiring Diagrams 24 VAC Transformer 2 4 Actuators may be connected in parallel. Power consumption and input impedance must be observed. Up to 4 actuators may be connected in parallel. With 4 actuators wired to one 500 Ω resistor, a +2% shift of control signal may be required. Power consumption must be observed. 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (—) leg of control circuits.
TFRX24-MFT Actuators, Multi-Function Technology 3.05" [76.2] D09 94 Dimensions with 2-Way Valve 6.28" [159.55] 2.4 [6 2.93" [74.5] B Valve Body B207-B211 B212-B215 B217-B221 Models Valve Nominal Size Inches DN [mm] ½” 15 ½” 15 ¾” 20 Dimensions (Inches [mm]) A B 2.41” [61.1] 1.39” [35.2] 2.38” [60.4] 1.78” [45.2] 2.73” [69.3] 1.87” [47.
TFRX24-MFT Actuators, Multi-Function Technology 1 2 W024 Wiring Diagrams Provide overload protection and disconnect as required. CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 4 ZG-R01 may be used. WARNING Live Electrical Components! O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
LF Actuators, On/Off D073 Dimensions with 2-Way Valve 3.625" [92] 7.64" [194] 2.28" [58] 3.7" [94] B A Valve Body B207(B)-B211(B) B212(B)-B215(B) B217(B)-B220(B) B222-B225 B229-B230 Models w/built-in Aux. Switch w/built-in Aux. Switch Technical Data Control Power supply LF24(-S) US LF120(-S) US Dimensions with 3-Way Valve D026 on/off, floating point LF120(-S) US Power consumption LF24(-S) US 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 120 VAC ± 10% 50/60 Hz running holding running holding 5W 2.5 W 5.
LF Actuators, On/Off Wiring Diagrams 24 VAC Transformer 1 2 Line Volts Provide overload protection and disconnect as required. CAUTION Equipment damage! 1 Common 2 + Hot LF24 US Actuators may be connected in parallel. Power consumption must be observed. 3 2 On/Off wiring for 24 VDC 3 Actuator may also be powered by 24 VDC. 4 For end position indication, interlock control, fan startup, etc., LF24-S US and LF120-S US incorporates a built-in auxiliary switch: 1 x SPDT, 6A (1.
LF24-3 Actuators, Floating Point D073 Dimensions with 2-Way Valve 3.625" [92] 7.64" [194] 2.28" [58] 3.7" [94] B A Valve Body B207(B)-B211(B) B212(B)-B215(B) B217(B)-B220(B) B222-B225 B229-B230 w/built-in Aux.
LF24-3 Actuators, Floating Point W054 Wiring Diagrams 24 VAC Transformer Line Volts CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption must be observed. 3 Actuators may also be powered by 24 VDC. 4 The common connection from the actuator must be connected to the Hot connection of the controller. 5 The actuator Hot must be connected to the control board common.
LF24-SR Actuators, Proportional D073 Dimensions with 2-Way Valve 3.625" [92] 7.64" [194] 2.28" [58] 3.7" [94] B A Valve Body B207(B)-B211(B) B212(B)-B215(B) B217(B)-B220(B) B222-B225 B229-B230 w/built-in Aux.
LF24-SR Actuators, Proportional Wiring Diagrams 4 24 VAC Transformer 2 Blk (1) Common Line Volts CAUTION Equipment damage! Actuators may be connected in parallel. Up to 4 actuators may be connected in parallel. With 4 actuators wired to one 500 Ω resistor, a +2% shift of control signal may be required. Power consumption must be observed. Red (2) + Hot Control Signal (–) 2 to 10 VDC (+) Grn (5) U Output, 2 to 10V 7 CW 3 Actuators may also be powered by 24 VDC.
LF24-MFT Actuators, Multi-Function Technology 3.625" [92] D073 Dimensions with 2-Way Valve 7.64" [194] 2.28" [58] 3.7" [94] B A Valve Body B207-B211 B212-B215 B217-B220 B222-B225 B229-B230 w/built-in Aux.
LF24-MFT Actuators, Multi-Function Technology Wiring Diagrams 2 24 VAC/DC Transformer Line Volts CAUTION Equipment damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Actuators may also be powered by 24 VDC. 4 IN4004 or IN4007 diode (IN4007 supplied, Belimo part number 40155). 5 Triac A and B can also be contact closures.
AFRB Actuators, On/Off AFRB24(-S), AFRX24(-S) Actuators, On/Off Dimensions Models AFRB24 AFRB24-S AFRX24 AFRX24-S Power consumption Transformer sizing Electrical connection AFRB24... AFRX24... Overload protection Control Direction of rotation Angle of rotation Running time Position indication Manual override Ambient temperature Storage temperature Housing Agency listings † Noise level Quality standard 24 VAC ± 20% 50/60 Hz 24 VDC +20% / -10% running 5 W holding 2.5 W 7.
AFRB24(-S), AFRX24(-S) Actuators, On/Off 1 2 3 4 24 VAC Transformer 1 Common Line Volts Provide overload protection and disconnect as required. CAUTION Equipment Damage! 2 + Hot 3 Actuators may be connected in parallel. Power consumption and input impedance must be observed. AFB24, AFB24-S AFX24, AFX24-S Actuators may also be powered by 24 VDC. For end position indication, interlock control, fan startup, etc., AFRB24-S and AFRX24-S incorporates two built-in auxiliary switches: 2 x SPDT, 3A (0.
AFRBUP(-S), AFRXUP(-S) Actuators, On/Off Dimensions Models AFRBUP AFRBUP-S AFRXUP AFRXUP-S Power consumption Transformer sizing Electrical connection AFRBUP... AFRXUP... Overload protection Control Direction of rotation Angle of rotation Running time Position indication Manual override Ambient temperature Storage temperature Housing Agency listings † Noise level Quality standard 24 to 240 VAC -20% / +10%, 50/60 Hz 24 to 125 VDC +10% running 7 W holding 3.5 W 7 VA @ 24 VAC (class 2 power source) 8.
AF24-SR Actuators, Proportional AFRBUP(-S), AFRXUP(-S) Actuators, On/Off 2 3 4 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. No ground connection is required. For end position indication, interlock control, fan startup, etc., AFRBUP-S and AFRXUP-S incorporates two built-in auxiliary switches: 2 x SPDT, 3A (0.
AFRB24-SR, AFRX24-SR Proportional, Spring Return, 24 V, for 2 to 10 VDC or 4 to 20 mA Control Signal AFR_DIM Dimensions (Inches [mm]) Technical Data Power consumption Transformer sizing Electrical connection AFRB... 24 VAC ±20%, 50/60 Hz 24 VDC +20% / -10% running 5.5 W holding 3 W 8.5 VA (class 2 power source) AFX...
AFRB24-SR, AFRX24-SR Proportional, Spring Return, 24 V, for 2 to 10 VDC to 4 to 20 mA Control Signal Accessories WARNING G Live Electrical Components! ZG-AFB ZG-AFB118 ZS-100 ZS-150 ZS-260 ZS-300 NOTE: When using AFRB24-SR, AFRB24-SR-S, AFRX24-SR and AFRX24-SR-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to Belimo Wiring Guide.
AFRX Actuators, Multi-Function Technology 9.77” [248.2] 3.93” [99.9] 2.50” [63.5] 4.04” [102.7] AFRX_2WayValve-B207-B220 Dimensions Models Overload protection Feedback output* Input impedance Angle of rotation Direction of Rotation* spring motor Position indication Manual override Running time motor* spring Ambient temperature Housing Agency listings Noise level Quality standard † Programmed for 70 sec motor runtime. At 150 sec motor run time, transformer sizing Dimensions 9.77” [248.2] 4.
W600_AFB_AFX AFRX Actuators, Multi-Function Technology 9.77” [248.2] AFR_LGCCV Dimensions 3.93” [99.9] 2.50” [63.5] 4.04” [102.7] A C AFB24-MFT-S AFX24-MFT-S B Valve Body Nominal Pipe Size B6250 2½" [65] B6300 3" [80] B6400 4" [100] Top Flange Design Flange Diameter Face-to-Face Length Height A B C W399_08 Auxiliary Switches for AFRX24-MFT 7.50" [190.5] 5.50" [139.7] 8.10" [205.4] F05 8.00" [203.2] 6.60" [167.6] 8.40" [213.1] 9.00" [228.6] 8.30" [210.8] 9.30" [235.
AFRX24-MFT95 Actuator, Proportional Potentiometric Control 9.77” [248.2] 3.93” [99.9] 2.50” [63.5] 4.04” [102.7] AFRX_2WayValve-B207-B220 Dimensions Models AFRX24-MFT95 spring motor Position indication Manual override Running time motor* spring Ambient temperature Housing Agency listings Noise level Quality standard † Programmed for 70 sec motor runtime. At 150 sec motor run time, transformer sizing is 8.5 VA and power consumption is 6 W running/3 W holding.
AFRX24-MFT95 Actuator, Proportional Potentiometric Control 9.77” [248.2] AFR_LGCCV Dimensions 4.04” [102.7] Switch A Switch B Damper Open Damper Closed 2.50” [63.5] 3.93” [99.9] Damper Position The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire R.
AFRX24-MFT95 Actuator, Proportional Potentiometric Control AFRX24-MFT95 AFRX24-MFT95 AFRX24-MFT95 Wiring multiple actuators to a Series 90 controller. AFRX24-MFT95 AFRX24-MFT95 AFRX24-MFT95 Wiring multiple actuators to a Series 90 controller using a minimum position potentiometer. AFRX24-MFT95 with the W973, W7100 and T775 controllers. 800-543-9038 USA 98 866-805-7089 CANADA 203-791-8396 LATIN AMERICA O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
AFRB24-5-14, AFRB24-S-5-14 Actuators, On/Off 9.77” [248.2] AFR_LGCCV Dimensions 3.93” [99.9] 2.50” [63.5] 4.04” [102.7] A C B Models AFRB24-5-14 AFRB24-S-5-14 Technical Data Power supply Power consumption Transformer sizing Electrical connection AFRB24... O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc. AFRX24...
AFRB24-5-14, AFRB24-S-5-14 Actuators, On/Off 1 2 3 4 24 VAC Transformer 1 Common Line Volts Provide overload protection and disconnect as required. CAUTION Equipment Damage! 2 + Hot 3 Actuators may be connected in parallel. Power consumption and input impedance must be observed. AFB24, AFB24-S AFX24, AFX24-S Actuators may also be powered by 24 VDC. For end position indication, interlock control, fan startup, etc.
AFRBUP-5-14, AFRBUP-S-5-14 Actuators, On/Off 9.77” [248.2] AFR_LGCCV Dimensions 3.93” [99.9] 2.50” [63.5] 4.04” [102.7] A C B Models AFRBUP-5-14 AFRBUP-S-5-14 Technical Data Power supply Power consumption Transformer sizing Electrical connection AFRBUP... O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc. AFRXUP...
AFRBUP-5-14, AFRBUP-S-5-14 Actuators, On/Off 2 3 4 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. No ground connection is required. For end position indication, interlock control, fan startup, etc., AFRBUP-S and AFRXUP-S incorporates two built-in auxiliary switches: 2 x SPDT, 3A (0.5A) @250 VAC, UL Approved, one switch is fixed at +10°, one is adjustable 10° to 90°.
GKRB24-3-5-14 Actuators, On/Off, Floating Point, Fail-Safe 2.36” [60] 3.43” [87] Dimensions 7.05” [179] C B Models Valve Body Nominal Pipe Size B6500 5" [125] B6600 6" [150] GKRB24-3-5-14 Technical Data Control Power supply Power consumption Transformer sizing Electrical connection O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
GKRB24-3-5-14 Actuators, On/Off, Floating Point, Fail-Safe Electrical Installation Wiring Diagrams T – ~ Wiring diagram + Note ! • Connect via safety isolation transformer. • Parallel connection of other actuators possible. Note performance data for supply. DC 0 ... 10 V Y U 1 2 3 DC 2 ... 10 V 1 Provide overload protection and disconnect as required. 2 CAUTION N Equipment Damage! 3 Actuators may also be powered by 24 VDC.
GKRX24-MFT-5-14 Actuators, Multi-Function Technology, Fail-Safe 2.36” [60] 3.43” [87] Dimensions 7.05” [179] C B Valve Body Nominal Pipe Size B6500 5" [125] B6600 6" [150] A Top Flange Design Models GKRX24-MFT-5-14 Technical Data Control Power supply Power consumption O50905 - 05/12 - Subject to change. © Belimo Aircontrols (USA), Inc.
GKRX24-MFT-5-14 Actuators, Multi-Function Technology, Fail-Safe 1 Provide overload protection and disconnect as required. 2 CAUTION N Equipment Damage! 3 Actuators may also be powered by 24 VDC. 5 8 9 Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible.
Accessories Application The CCV-EXT-KIT can be used with most CCV’s* and PICCV in order to achieve a large clearance over the pipe. The Extension Kit will provide an additional 2” of space between the top of the valve and the base of the actuator. bracket is made from aluminum and is not intended as a thermal block. – Extension kit will be automatically assembled with any Flanged CCV assembly. Available for Spring g and Non-Spring Non Spring Actuators Technical Data Extension Height Total Weight 2" 0.
Accessories ZS-CCV... New Characterized Control Valve Weather Shield Application The ZS-CCV... weather shield provides moderate protection for valves which are mounted outdoors. This product is designed as a water tight enclosure. The housing allows easy mounting over the actuator, while allowing easy viewing of the actuator in operation. Weather shield for PICCV/CCV to provide protection for actuators in outdoor applications.
Accessories Auxiliary Switches S1A, S2A For non-spring return direct-coupled actuators Application The S1A and S2A auxiliary switches are used to indicate when a desired position of a valve is reached or to interface additional controls for a specific control sequence. Operation The S1A and S2A auxiliary switches are mounted onto the direct coupled actuator.
Accessories Feedback Potentiometer P...A For the non-spring return direct-coupled actuators Application The P…A feedback potentiometers are used with LR and AR actuators to provide a resistive signal which varies with valve position. The P…A units are applied with commercial proportional temperature controllers to provide feedback of the valve position, or with electric or electronic meters to provide position indication.
Wiring Accessories Protective Terminal Cover For the non-spring return direct-coupled actuators Application Belimo non-spring return actuators with terminal strips are can be converted from NEMA 1/IP20 to NEMA 2/IP54 using the protective terminal cover ZS-T. The ZS-T terminal cover accessory consists of: • Terminal Cover • Conduit Fitting • Rubber Seal for Wire Diameter 4-6 • Rubber Seal for Wire Diameter 6-8 Terminal Cover Conduit Fitting Rubber Seals Mounting the Terminal Cover 1.
MFT Standard Configuration Code P-10001 P-10002 P-10003 P-10004 P-10005 P-10006 P-10007 P-10009 P-10010 P-10013 P-10015 P-10016 P-10017 P-10018 P-10020 P-10028 P-10031 P-10063 P-10064 P-20001 P-20002 P-20003 P-20004 P-20005 P-30001 P-30002 P-30003 P-30004 P-30005 P-30006 P-40001 P-40002 P-40003 P-40004 P-40005 A01 A02 A03 A04 A05 A06 A07 A09 A10 A13 A15 A16 A17 A18 A20 A28 A31 A63 A64 W01 W02 W03 W04 W05 F01 F02 F03 F04 F05 F06 J01 J02 J03 J04 J05 Control Motion Input Range Position Feedback Running
MFT Programming Codes, Flexible Products PRODUCTS Base Actuator Codes LRX24-3 LR000 LR030 LRX24-SR LRX24-PC LRXX0† LR100 LRX24-MFT LRX24-MFT95 LRXX0† LRX120-3 LR060 LRX120-SR LR450 Control Input Feedback Running Time On/Off, Floating Point 2-10 VDC (4-20mA*) 0-20 V Phasecut 2-10 VDC (Default) 0 to 135 Ohm On/Off, Floating Point 2-10 VDC (4-20mA*) — — 2-10 VDC 2-10 VDC 2-10 VDC — — 95 (Default) 95 (Default) 95 (Default) 150 (Default) 150 (Default) 95 (Default) 95 (Default) Angle of Rotation/Stroke 95
Custom MFT Configuration Order Form FAX: USA Toll Free 1-800-228-8283 #1 Select an Actuator (use one sheet for each unique actuator/configuration) ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ AF24-MFT US AF24-MFT-S US NF24-MFT US LF24-MFT US LF24-MFT-S US AF24-MFT95 US NV24-MFT US NVF24-MFT US NVF24-MFT-E US NVFD24-MFT US NVFD24-MFT-E US GMX24-MFT GMX24-MFTX1 Quantity ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ AMX24-MFT AMX24-MFTX1 NMX24-MFT NMX24