Datasheet

For more Information
please call
1-800-Belden1
General Description:
24 AWG stranded (7x32) tinned copper conductors, conductors cabled, semi-rigid PVC insulation, overall
Beldfoil® shield (100% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
10 24 7x32 TC - Tinned Copper
Total Number of Conductors: 10
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.254
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Outer Shield Material Coverage (%)
Beldfoil® Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24 7x32 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.8128
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1 Black
2 White
3 Red
4 Green
5 Brown
6 Blue
7 Orange
8 Yellow
9 Purple
10 Gray
Overall Nominal Diameter: 6.198 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +80°C
UL Temperature Rating: 80°C (UL AWM Style 2464)
Bulk Cable Weight: 55.063 Kg/Km
Max. Recommended Pulling Tension: 244.651 N
Min. Bend Radius/Minor Axis: 63.500 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 2464 (300 V 80°C)
Page 1 of 2 01-05-2017
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9540 Multi-Conductor - Computer Cable for EIA RS-232 Applications

Summary of content (2 pages)