Datasheet
PAIRED CABLES
5.38
Belden Electronics Division Technical Support: 1-800-BELDEN-1 or 1-800-BELDEN-3 • www.belden.com
22 AWG Stranded (7x30) • Tinned Copper • Twisted Pairs • Individually Shielded with 100% Beldfoil
®
• 22 AWG Stranded TC Drain Wire
Semi-rigid PVC Insulation • Pale Fawn Beige PVC Jacket (Shielded Pairs Parallel under Jacket)
UL AWM Style 2464 9406 NEC: 2 Black & 100 30.5 4.2 1.9 15.0Ω/M′ 13.0Ω/M′ .173 4.39 50 60% 50 164 95 312
(300V 80°C) CMG
White,
U-500 U-152.4 16.5 7.5 49.2Ω/km 42.7Ω/km
xx
CEC:
Black &
500 152.4 17.0 7.7 .280 7.11
CMG FT4 Yellow U-1000 U-304.8 33.0 15.0
1000 304.8 33.0 15.0
22 AWG Stranded (7x30) • Tinned Copper • Twisted Pairs • Individually Shielded with 100% Beldfoil • 24 AWG Stranded TC Drain Wire
Polypropylene Insulation • Chrome PVC Jacket (Pairs Cabled on Common Axis to Reduce Diameter)
300V RMS 60°C 8723 NEC: 2 Red & 100 30.5 2.3 1.0 15.0Ω/M′ 16.6Ω/M′ .168 4.27 45 66% 35 115 62 203
CM
Black,
U-500 U-152.4 10.5 4.8 49.2Ω/km 54.5Ω/km
CEC:
Green &
500 152.4 10.0 4.5
CM White U-1000 U-304.8 20.0 9.1
1000 304.8 20.0 9.1
1640 499.9 32.8 14.9
U-2000 U-609.6 40.0 18.2
2000 609.6 40.0 18.2
3280 999.7 65.6 29.8
5000 1524.0 95.0 43.2
10000 3048.0 200.0 90.9
Plenum • Halar
®
Insulation • Natural Flamarrest
®
Jacket (Pairs Cabled on Common Axis to Reduce Diameter)
300V RMS, Non-conduit 82723 NEC: 2 Red & U-500
†
U-152.4 10.0 4.5 14.7Ω/M′ 16.6Ω/M′ .148 3.76 36 62% 43 141 75 246
CMP
Black,
U-1000
†
U-304.8 19.0 8.6 48.2Ω/km 54.5Ω/km
CEC:
Green &
1000
†
304.8 20.0 9.1
CMP FT6 White U-2000
†
U-609.6 38.0 17.3
Plenum • FEP Insulation • Red FEP Jacket (Pairs Cabled on Common Axis to Reduce Diameter)
300V RMS, Non-conduit 88723 NEC: 2 Red & 100 30.5 3.4 1.5 16.0Ω/M′ 14.7Ω/M′ .148 3.76 40 69% 35 115 67 220
CMP
Black,
500 152.4 11.0 5.0 52.5Ω/km 48.2Ω/km
CEC:
Green &
1000 304.8 21.0 9.5
CMP FT6 White
Plenum • FEP Insulation • Red Fluorocopolymer Jacket (Pairs Cabled on Common Axis to Reduce Diameter)
300V RMS, Non-conduit 87723 NEC: 2 Red & 500
†
152.4 11.0 5.0 16.0Ω/M′ 14.7Ω/M′ .148 3.76 40 69% 35 115 67 220
CMP
Black,
1000
†
304.8 20.0 9.1 52.5Ω/km 48.2Ω/km
CEC:
Green &
CMP FT6 White
DCR = DC Resistance • TC = Tinned Copper
*Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
†
Spools and/or UnReel
®
cartons are one piece, but length may vary ±10% for spools and ±5% for UnReel from length show.
Individually Shielded
Audio, Control and Instrumentation Cables
Plenum-Rated and Non-Plenum
UL NEC/
C(UL) CEC
Type
Part
No.
No.
of
Pairs
Ft. m
Standard
Lengths
Standard
Unit Weight
Lbs. kg
Nom. DCR
Cond. Shield
Description
Color
Code
Nominal
OD
Inch mm
Nom.
Imp.
(Ω)
Nom.
Vel.
of
Prop.
Nom. Capacitance
*
pF/
Ft.
*
pF/
m
**
pF/
Ft.
**
pF/
m
Z-Fold
®
Z-Fold
®
Z-Fold
®
Z-Fold
®
Z-Fold
®
For Plenum versions of 8723,
see 88723, 87723 or 82723.