8723 Paired - Shielded Twisted Pair Cable
Outer Jacket Material PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter .160 in.
MECHANICAL CHARACTERISTICS:
Operating Temperature Range -30°C To +60°C
UL Temperature Rating 60°C
Bulk Cable Weight 18.3 lbs/1000 ft.
Max. Recommended Pulling Tension 50 lbs.
Min. Bend Radius (Install) 1.6 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification CM
CEC/C(UL) Specification CM
EU CE Mark (Y/N) Yes
EU RoHS Compliant (Y/N) Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
FLAME TEST:
UL Flame Test UL1685 UL Loading
PLENUM/NON-PLENUM:
Plenum (Y/N) N
Plenum Number 82723, 87723, 88723, 1325A
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance 45 Ohms
Nom. Inductance 0.17 µH/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz 35 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 62 pF/ft
Nominal Velocity of Propagation 66 %
Nom. Conductor DC Resistance @ 20 Deg. C 14.7 Ohms/1000 ft
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C 15 Ohms/1000 ft
Max. Operating Voltage - UL 300 V RMS
Max. Recommended Current 2.3 Amps per conductor @ 25°C
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
8723 060100 2 SH PR #22 PP PVC
100 2.3 CHROME
8723 0601000 2 SH PR #22 PP PVC
1000 20 CHROME
C
Page 2 of