Datasheet

7805 Coax - RG-174 Type
Operating Temperature Range -40°C To +75°C
Non-UL Temperature Rating 80°C
Bulk Cable Weight 9 lbs/1000 ft.
Max. Recommended Pulling Tension 16 lbs.
Min. Bend Radius (Install) 0.25 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
EU CE Mark (Y/N) No
EU RoHS Compliant (Y/N) Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
SUITABILITY:
Suitability - Outdoor Yes
Suitability - Aerial Yes - When supported by a messenger
Suggested Connectors Mates with standard RG-174 connectors.
PLENUM/NON-PLENUM:
Plenum (Y/N) N
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance 50 Ohms
Nom. Inductance .077 µH/ft
Nom. Capacitance Conductor to Shield 31.2 pF/ft
Nominal Velocity of Propagation 66 %
Nominal Delay 1.54 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C 32.0 Ohms/1000 ft
Nominal Outer Shield DC Resistance @ 20°C 9.1 Ohms/1000 ft
Maximum VSWR :
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Maximum VSWR
5 6000 1.25:1
Nom. Attenuation :
Page 2 of
4