Datasheet
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
RG Type: 59/U
Flame Test
UL Flame Test: UL1685 UL Loading
Suitability
Suitability - Indoor: Yes
Suitability - Outdoor: Yes - Black Only
Suitability - Aerial: Yes - Black only, when supported by a messenger wire
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.308414
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
55.777
Nominal Velocity of Propagation:
VP (%)
80
Nominal Delay:
Delay (ns/m)
4.2653
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
40.0282
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
7.8744
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1.000 0.656
3.600 1.641
5.000 1.969
6.000 2.198
7.000 2.395
10.000 2.953
12.000 3.215
25.000 4.725
67.500 7.874
71.500 8.203
88.500 9.187
100.000 9.843
135.000 11.484
143.000 11.812
180.000 13.452
270.000 16.733
Page 2 of 3 03-16-2009
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1505F Coax - RG-59/U Type