Datasheet

For more Information
please call
1-800-Belden1
Description:
20 AWG solid .032" bare copper conductor, gas-injected foam HDPE insulation, Duofoil® + tinned copper
braid shield (95% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (in.)
1 20 Solid BC - Bare Copper .032
Insulation
Insulation Material:
Insulation Material Dia. (in.)
Gas-injected FHDPE - Foam High Density Polyethylene .145
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid TC - Tinned Copper 95
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cabling
Overall Nominal Diameter: 0.233 in.
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +75°C
UL Temperature Rating: 75°C
Bulk Cable Weight: 31 lbs/1000 ft.
Max. Recommended Pulling Tension: 47 lbs.
Min. Bend Radius (Install)/Minor Axis: 2.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMR
CEC/C(UL) Specification: CMG
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005
EU Directive 2002/96/EC (WEEE): Yes
Page 1 of 4 10-16-2009
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1505A Coax - RG-59/U Type
Der Außendurchmesser dieses Kabel
entspricht: 6,0 mm (+/- 0,1 mm)
(Overall Nominal Diameter: 0,233 in)