Data Sheet

For more Information
please call
1-800-Belden1
General Description:
20 AWG stranded (7x28) bare copper conductors, foam HDPE insulation, overall Beldfoil® shield (100%
coverage) plus tinned copper braid shield (78% coverage), 22 AWG stranded (19x34) tinned copper drain
wire, PVC jacket.
Usage (Overall)
Suitable Applications: CC Link
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
3 20 7x28 BC - Bare Copper
Total Number of Conductors: 3
Insulation
Insulation Material:
Insulation Material
FHDPE - Foam High Density Polyethylene
Insulation Color Code Chart:
Number Color
1 Blue
2 Yellow
3 White
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Beldfoil® Tape Aluminum Foil-Polyester Tape 100
2 Braid TC - Tinned Copper 78
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
22 19x34 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.889
Overall Cable
Overall Nominal Diameter: 7.696 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +60°C
Bulk Cable Weight: 72.922 Kg/Km
Max. Recommended Pulling Tension: 204.617 N
Min. Bend Radius/Minor Axis: 76.200 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
Page 1 of 2 08-26-2016
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1348A Multi-Conductor - CC Link Certified Cable