15. ALARMS/RELAY SCREEN
SCREEN SELECTABLE DATA
To select a parameter click on the screen, then select the event using the knob, and click again. Use the encoder to select the event parameter and click,
set the new value, and click again. To exit the event, select it, and click. The events scroll as the cursor is moved thru the list. To exit this screen, select
the screen icon and click on it.
Events can be set to trigger any one of four relay closures, 4 email addresses, or display in a popup alarm window on the FMCS-1.
Alarm Status is indicated with a multi-colored graphical LED. Red indicates the alarm is active, yellow indicates the alarm has met the threshold but not
the time criterion, green indicates no alarm condition.
Loss of RF (ANT): Loss of RF on Antenna Input, Threshold −10.0 to −80dB; Time 1 to 60 sec
Loss of RF (HL): Loss of RF on High Level Input, Threshold 0 to 100.0%; Time 1 to 60 sec
High AM Noise: High AM Noise Level, Threshold −20.0 to −80.0dB; Time 1 to 60 sec
High SYNC Noise: High AM Synchronous Noise Level, Threshold −20.0 to −80.0dB; Time 1 to 60 sec
Loss of Total: Loss of Peak Total Modulation, Threshold 0 to 100.0%; Time 1 to 60 sec
Total Peak LED: Total Peak Level Exceeded, Threshold 0 to 150.0%; Time N/A
Loss of L+R: Loss of L+R or Mono program, Threshold 0 to 100.0%; Time 1 to 60 sec
Loss of Pilot: Indicates Pilot Tone is present, Threshold 0 to 15.0%; Time 1 to 60 sec.
Loss of RDS: Indicates RDS subcarrier is present, Threshold 0 to 10.0%; Time 1 to 60 sec
Loss of RDS SYNC: Indicates RDS decoder has synced to RDS data stream and is decoding data, Threshold N/A; Time 1 to 60 sec
Loss of SCA#1: Indicates SCA#1 subcarrier is present, Threshold 0 to 25.0%; Time 1 to 60 sec
SCA#1 Peak LED: SCA#1 Peak Modulation Level Exceeded, Threshold 0 to 150.0%; Time 1 to 60 sec
Loss of SCA#2: Indicates SCA#2 subcarrier is present, Threshold 0 to 25.0%; Time 1 to 60 sec
SCA#2 Peak LED: SCA#2 Peak Modulation Level Exceeded, Threshold 0 to 150.0%; Time 1 to 60 sec