Datasheet

39200 Series
Shielded Plug Assembly Instructions
Bel Stewart Connector Page 2 of 2 MN390016 Rev A0
08
Remove the terminated plug from the
tool .
Repeat this procedure for the other end
of the cable.
Inspect and test your cable.
07
Trim off any excess shield.
If using a boot, insert the boot tight
against the back of the plug body.
Make sure that the plug latch tab is under
the anti-snag.
Fully insert the plug into the termination
tool and close the handle.
06
Insert the load bar and wires into the back of
the plug housing keeping the plug contacts
toward you.
Push the load bar in until it is fully seated
against the front of the plug housing.
Ensure that the ends of the wires have not
backed out of the load bar and are still flush
with the front edge.
Insert the ends of the wires into the load
bar keeping wedge toward you (see pic-
ture).
Pull the wires through the load bar and
seat the load tight against the wire
aligner.
Trim off the wires flush to the end of the
load bar
05
PUSH
LOAD BAR
OVER WIRES
WEDGE