Datasheet
39200 Shielded Large Conductor
Plug Assembly Instructions
Bel Stewart Connector Page 2 of 2 MN390015 Rev A0
Bend the solid color wires down slightly.
Insert the ends of the wires into the load
bar keeping the slots toward you (see
picture).
Pull the wires through the load bar and
seat the load tight against the wire
aligner.
Trim off the wires flush to the end of the
load bar
05
BEND 4 SOLID COLOR WIRES
(2, 4, 6, & 8) DOWNWARD
SIDE OF LOAD BAR
WITH SLOTS
PUSH LOAD BAR OVER WIRES
07 08
If using shielded cable, the shield fingers
should contact the foil, drain wire and/or
braid.
Fully insert the plug into the termination
tool and close the handle.
Remove the terminated plug from the tool
using the release button.
Trim off any excess shield if used and
snap the boot in place.
Inspect and test your cable.
BEND
BEND
06
Insert the load bar and wires into the back of
the plug housing keeping the plug contacts
toward you.
Push the loadbar in until it is fully seated
against the front of the plug housing.
Ensure that the wires have not backed out of
the load bar.
Bend shield fingers in toward the cable.