Datasheet
Bel Stewart Connector
Instruction Sheet MN390011
Page 1 of 8 Rev A1
PLUG ASSEMBLY INSTRUCTIONS FOR
Cable with INDIVIDUALLY SHIELDED PAIRS (PIMF or SFTP)
T568B Wiring Pattern
For Cable with Overall Foil Shield (FTP), See Page 9
TAPERED END
OF PLASTIC
WIRE ALIGNER
5
OTHER END OF CABLE SHOWING GREEN
PAIR IN FRONT
BROWN PAIR
ORANGE PAIR
Place plastic wire aligner between the pairs. The tapered end should be toward the braid and jacket. The orange pair will
go to the deep channel on the left side and the brown pair will go toward the deep channel on the right. The blue and
green pairs will go to the sides that have shallow channels at the middle.
Cut and strip off 1 to 1
1
/
4
inches of the outer jacket.
Be careful not to cut or nick the braid and foil shields.
2
Cut cable to length. If you are using a strain relief
grommet, slide it over the cable. The larger ends should
be facing outward, toward the plug end of the cable.
1
¼ INCH
Spread out the 4 wire pairs and trim foil to ¼
inch on all 4 pairs.
4
Pull the braid back over the cable
j
acket.
3
1 to 1 ¼
INCHES