RoHS
Bel Stewart Connector GREEN END Shielded 39200 Series Assembly Instructions Individually Shielded Pair Cable 11118 Susquehanna Trail South Glen Rock, PA 17327 BLUE END With Orange Orange on left and Brown on right, one end of cable has Green on top, other end has Blue on top. Green end steps will be shown on left, Blue steps shown on right. Common steps will be in the middle. INDIVIDUALLY SHIELDED PAIRS For Cable with Overall Shield See Page 6 1 Trim off approx. 1.75 to 2.
Shielded 39200 Series Assembly Instructions Individually Shielded Pair Cable Bel Stewart Connector 11118 Susquehanna Trail South Glen Rock, PA 17327 GREEN BLUE 0.375” 0.375” 4b 4g Trim individual pair shields, leaving approximately 0.
Shielded 39200 Series Assembly Instructions Individually Shielded Pair Cable Bel Stewart Connector 11118 Susquehanna Trail South Glen Rock, PA 17327 GREEN BLUE 8g 8b Fold Grn pair back Split Grn pair around Blu pair, then fold back 9 Org Blu and Brn pairs @ slight angle to Trim ends of Org, make loading easier 10g 10b Insert Org Blu and Brn pairs into load bar Leave load bar near end of pairs 11g 11b Bring up Grn pair and trim so it fits into load bar Page 3 of 10 MN390009-A2
Shielded 39200 Series Assembly Instructions Individually Shielded Pair Cable Bel Stewart Connector 11118 Susquehanna Trail South Glen Rock, PA 17327 GREEN BLUE 12g 12b Slide load bar down to base of pairs 3/16” 3/16” 13b 13g Trim off wire ends at approx. 0.
Bel Stewart Connector 16 17 18 Page 5 of 10 Shielded 39200 Series Assembly Instructions Individually Shielded Pair Cable 11118 Susquehanna Trail South Glen Rock, PA 17327 Close shield fingers by hand Verify wires are visible through end of plug Crimp contacts and shield fingers.
Bel Stewart Connector Shielded 39200 Series Assembly Instructions Overall Shield Cable 11118 Susquehanna Trail South Glen Rock, PA 17327 OVERALL SHIELD For Cable with Individual Shielded Pairs See Page 1 1 Trim off approx. 1.75 to 2.00 inches of cable jacket Do not nick shield 2 Fold shield back over cable jacket 0.25 3 Wrap drain around cable ¼” (0.
Shielded 39200 Series Assembly Instructions Overall Shield Cable Bel Stewart Connector 11118 Susquehanna Trail South Glen Rock, PA 17327 GREEN BLUE 5b 5g Untwist individual pairs to approximately 0.
Shielded 39200 Series Assembly Instructions Overall Shield Cable Bel Stewart Connector 11118 Susquehanna Trail South Glen Rock, PA 17327 GREEN BLUE 9 Trim ends of Org, Org Blu and Brn pairs @ slight angle to make loading easier 10 Insert Org Org Blu and Brn pairs into load bar Leave load bar near end of pairs 11g 11b Bring up Grn pair and trim so it fits into load bar 12g 12b Slide load bar down to base of pairs Page 8 of 10 MN390009-A2
Shielded 39200 Series Assembly Instructions Overall Shield Cable Bel Stewart Connector 11118 Susquehanna Trail South Glen Rock, PA 17327 GREEN BLUE 13 3/16” Trim off wire ends at approx. 0.
Bel Stewart Connector 17 11118 Susquehanna Trail South Glen Rock, PA 17327 Verify wires are visible through end of plug 18 19 Page 10 of 10 Shielded 39200 Series Assembly Instructions Overall Shield Cable Crimp contacts and shield fingers Trim off excess foil shield MN390009-A2