Specifications
Technical Specifications
16 DRYPOINT RA 80 – 720
4.2. Technical Specifications DRYPOINT RA 180-720 /AC
720
73600
4416
2600
0.26
DN125 PN16
11.00
8500
14.6
11000
17.9
700
600
60000
3600
2119
0.20
10.00
7500
12.8
9900
16.3
590
500
50000
3000
1766
0.14
9.80
6700
11.5
8900
15.0
580
400
40000
2400
1413
0.21
DN100 PN16
9.00
15500
6500
11.1
8600
14.6
< 80
530
360
36800
2208
1300
0.26
4.60
5000
9.0
6500
11.7
302
300
30000
1800
1060
0.19
4.00
4400
8.7
5700
11.2
277
250
25000
1500
883
0.13
3.20
6500
4300
8.1
5500
10.1
267
210
21000
1260
742
0.21
3.00
3500
6.3
5400
8.9
242
Air-Cooled
180
18000
1080
636
+3 equal to 0.73 g/m
3
of H
2
O
+25 (+50)
+1
+35 (+70)
7
14
0.17
DN80 PN16
R404A
2.70
5300
-
-
-
-
-
-
3/400-415/50
3350
5.6
4700
7.4
< 75
232
[l/min]
[m
3
/h]
[scfm]
[°C]
[°C]
[°C]
[°C]
[barg]
[barg]
[bar]
[BSP-F]
[kg]
[m
3
/h]
[m
3
/h]
[m
3
/h]
[°C]
[barg]
[BSP-F]
[Ph/V/Hz]
[W]
[A]
[W]
[A]
[dbA]
[kg]
DRYPOINT RA MODEL
Air flow rate at nominal condition
1
Pressure DewPoint at nominal condition
1
Nom. ambient temperature. (max.)
Min. ambient temperature
Nominal inlet air temperature. (max.)
Nominal inlet air pressure
Max. inlet air pressure
Air pressure drop - ∆p
Inlet - Outlet connections
Refrigerant type
Refrigerant quantity
3
Cooling air fan flow
Cooling water flow at 15°C (out 30°C)
Cooling water flow at 30°C (out 40°C)
Control of cooling water flow
Maximum water temperature
2
Min. (Max) water pressure
Cooling water connections
Standard Power Supply
3
Nominal electric absorption
Max. electric absorption
Max. level noise at 1 m
Weight
1
The nominal condition refers to an ambient temperature of +25°C with inlet air at 7 barg and +35 °C.
2
Other temperature on request.
3
Check the data shown on the identification plate.