3.2. First start-up
This procedure should be followed on first start-up, after periods of extended shutdown or following
maintenance procedures.
Qualified personnel must perform the start-up.
Sequence of operations (refer to paragraph 5.1 Control Panel).
DMC14 Electronic Instrument DMC20 Electronic Instrument
Ensure that all the steps of the “Installation” chapter
have been observed.
Ensure that the connection to the compressed air
system is correct and that the piping is suitably fixed
and supported.
Ensure that the condensate drain pipe is properly
fastened and connected to a collection system or
container.
Ensure that the by-pass system (if installed) is closed
and the dryer is isolated.
Ensure that the manual valve of the condensate drain
circuit is open.
Remove any packaging and other material which could
obstruct the area around the dryer.
Activate the mains switch.
Turn on the main switch - pos. 1 on the control panel.
Check that the mains detection light of the ON/OFF
button - pos. 4 of the control panel - is ON.
Wait at least two hours before starting the dryer
(compressor crankcase heater must heat the oil of the
compressor) - only models RA 180-720.
Ensure the cooling water flow and temperature is
adequate (Water-Cooled).
Switch ON the dryer pressing the button "I - ON" of the
ON/OFF switch - pos. 4 of the control panel.
Ensure that DMC14 electronic instrument is ON.
Ensure the consumption matches with the values of the
data plate.
Check that the rotation direction of the fan
corresponds with the arrows on the condenser (Air-
Cooled).
Allow the dryer temperature to stabilise at the pre-set
value.
Slowly open the air inlet valve.
Slowly open the air outlet valve.
Slowly close the central by-pass valve of the system (if
installed).
Check the piping for air leakage.
Ensure the drain is regularly cycling - wait for its first
interventions.
Ensure that all the steps of the “Installation” chapter
have been observed.
Ensure that the connection to the compressed air
system is correct and that the piping is suitably fixed
and supported.
Ensure that the condensate drain pipe is properly
fastened and connected to a collection system or
container.
Ensure that the by-pass system (if installed) is closed
and the dryer is isolated.
Ensure that the manual valve of the condensate drain
circuit is open.
Remove any packaging and other material which could
obstruct the area around the dryer.
Activate the mains switch.
Turn on the main switch - pos. 1 on the control panel.
Check that "crankcase oil heater" and "Stand-by" leds
on DMC20 are ON.
Wait at least two hours before starting the dryer
(compressor crankcase heater must heat the oil of the
compressor) - only models RA 180-720.
Ensure the cooling water flow and temperature is
adequate (Water-Cooled).
Switch ON the dryer keeping the “Dryer Start-up” button
on DMC20 pressed for at least 2 seconds.
Check that “compressor ON” led on DMC20 is ON.
Ensure the consumption matches with the values of the
data plate.
Check that the rotation direction of the fan
corresponds with the arrows on the condenser (Air-
Cooled).
Allow the dryer temperature to stabilise at the pre-set
value.
Slowly open the air inlet valve.
Slowly open the air outlet valve.
Slowly close the central by-pass valve of the system (if
installed).
Check the piping for air leakage.
Ensure the drain is regularly cycling - wait for its first
interventions.