Operating instructions
Installation
16 BEKOSPLIT® 11
During the installation, the legal provi-
sions need to be adhered to.
The following points need to be ob-
served in particular:
• Move the BEKOSPLIT
®
11 and the
preseparation containers only when
empty, and with suitable means of
transportation (e.g. on pallets.
• The BEKOSPLIT
®
11 is top-heavy.
Watch for protruding parts.
Area of installation
• Do not install in places where frost
is likely to occur or outdoors!
• Sealed floor area or collection basin!
In the event of damage, untreated
condensate or oil must not leak into
the sewerage system or the soil!
• Install the BEKOSPLIT
®
11 horizon-
tally on an even, smooth floor.
• Tightly screw the oil receiver to the
oil drain of the preseparation con-
tainer using the included connection
kit.
Inlet
• Install the condensate manifold (1)>
G1 with a slight downward slope to
the preseparation container at the
wall, use the T-piece (3) as a
branch, and connect with the con-
densate inlet of the pressure relief
chamber (2) via hose line. (Installa-
tion height of the line higher than the
condensate inlet of the pressure re-
lief). The lines must be secured
against loosening, for example by
means of hose clamps (4).
• Connect preseparation tank and
BEKOSPLIT
®
11 using the ½” hose
supplied.
Outlet
• Fix the water drain hose at the water
outlet of the BEKOSPLIT
®
11, and
supply to the wastewater connection
with a constant slope. Use a siphon
as an odour trap.