User's Manual
84
2. If pushing from top entry is not working, then try push from bottom entry when the
nozzle is attached. Becareful not touch the heater block, wear gloves included.
3. If the pushing from both side are not working, user can try to remove the heater module
from the extruder, refer to previous pages of this chapter. Remove the PTFE tubes in the
heater module and then heat up the heater block on a torch light/bunsen burner/alcohol
lamp/stove flame. User may need to use tool to hold the heater block instead hold it by
hand and try push out the blockage.
4. If still cannot clean the heater block, the ultimate methods are to submerge the part in
acetone to dissolve the blockage or to heat the heater module on flame until the blocking
matter burn to ashes.
15.4Dual Filtration System
UP600 hasHEPA Filter and the Activated Carbon Filter. Both of the filters are located inside
the build chamber, circulating the air internally to reduce the toxic particles generated
during the 3D printing process.
We suggest you change the filter every 3 months, or every 300 hours active printing time.
You can purchase the new filtersfrom the official Tiertime online store,
https://shop.tiertime.com, or from local resellers
The filter system is located at the far side of the build chamber and have to be changed
from the back of the machine.