Users Manual Part 1
45
2. Path
Term
Unit
Description
Path Mode
Profile/Perimeter
N/A
Infill Density
%
Density of the infill pattern, 100%=solid infill, 0%=no infill
Support Density
mm
Full Fill Area
mm
2
Area threshold that override density to full/solid Infill. Area smaller
than this value will be printed 100% infill.
Infill Path
Top/Bottom Fill
N/A
Infill pattern for Top/Bottom
Offset/Zigzag/Line
Inner Fill
N/A
Infill pattern for Inner Fill
Offset/Zigzag/Line
Support Fill
N/A
Infill pattern for Support Fill
Offset/Zigzag/Line
Infill Profile
N/A
Extra inner perimeter for infill
None: no infill perimeter
Always: Always print infill perimeter
Alternate: print infill perimeter alternately, this option may increase
the contact surface area between perimeter and infill thus increase
the bond strength
Support Profile
N/A
Add a single perimeter to support column to increase stability of
support but may make support more difficult to remove.