User's Manual
Table Of Contents
- 1. FEATURES
- 2. DESCRIPTION
- 3. PINNING INFORMATION
- 4. Communication Protocol
- 4.1 Communication Setting
- 4.2 Communication Format
- 4.3 Command Overview
- 4-4. Command List
- 4-4-1 System Function Command
- 4-4-2 ISO14443A - Mifare Function Command
- 4-4-2-1. Request(Card A)
- 4-4-2-2. Anticollision(Card A)
- 4-4-2-3. Select card (Card A)
- 4-4-2-4. Halt (Card A)
- 4-4-2-5. Authenticate
- 4-4-2-6. Read block
- 4-4-2-7. Write block
- 4-4-2-8. Initialize electronic purse
- 4-4-2-9. Read purse value
- 4-4-2-10. Decrease purse value (including Transfer)
- 4-4-2-11. Increase purse value (including Transfer)
- 4-4-2-12. Restore purse value
- 4-4-2-13. Transfer
- 4-4-2-14. Get ATS of CPU A
- 4-4-2-15. Exchange data between PICC and PCD according with T = CL protocol
- 4-4-2-16. Ultralight card Anticoll and Select
- 4-4-2-17. Write a page of data into ultralight card
- 4-4-2-18. Authenticate password of Ultralight_C
- 4-4-2-19. Change password of Ultralight_C
- 4-4-2-20. SHC1102 card check password
- 4-4-2-21. Read data block of SHC1102 card
- 4-4-2-22. Write data block of SHC1102 card
- 4-4-2-23. Request DESFire and reset
- 4-4-2-24. Get version of Ntag213/216
- 4-4-2-25. Read page of data of Ntag213/216
- 4-4-2-26. Fast read page of data of Ntag213/216
- 4-4-2-27. Get NFC counter of Ntag213/216
- 4-4-2-28. Authenticate password of Ntag213/216
- 4-4-3 NFC Function Command
StrongLink SL060
http://www.stronglink-rfid.com
8
0x5402 Authenticate password of Ntag213/216
0x5502 Get ECC signature of Ntag213/216
0x0D01 Set the NFC field
0x0E01 Send the NFC command
Status Overview
Tab le 2
Status
Description
0x00
Operation successes
0x01
NFC connect fails
0x0A Operation fails
0x0B Command is not supported
0x0C Parameter is error
0x0D No cards
0x0E RF base station is damaged
0x14 Searching card fails
0x15 Reset card fails
0x16 Verifying key fails
0x17
Reading fails
0x18
Writing fails
4-4. Command List
4-4-1 System Function Command
4-4-1-1. Set baud rate
0xAA 0xBB Len DeviceID 0x01 0x01 Data Checksum
Data: 0x00: BaudRate = 4800
0x01: BaudRate = 9600(default)
0x02: BaudRate = 14400
0x03: BaudRate = 19200
0x04: BaudRate = 28800
0x05: BaudRate = 38400
0x06: BaudRate = 57600
0x07: BaudRate = 115200
After changing the BaudRate, further communication must be set as the new BaudRate.
Response:
0xAA
0xBB
Len
DeviceID
0x01
0x01
Status
Checksum
Status: 0x00: Operation succeed
0x0C: Parameter error
4-4-1-2. Initialize the Device ID
0xAA 0xBB Len DeviceID 0x02 0x01 Data Checksum
Data: 2 bytes device ID
Response: