4.7 Other Settings
Table 4-6 Setting application extension parameters
Parameters
Description
Default
Max log-in times
Max login times
5
Allow telnet
Enable or disable telnet funcation
No
Debug mode
Yes or no.
If yes is selected, you can view the DTU running logs
by using the serial port tool.
This setting take effect immediately, the restart is
unnecassary.
No
Debug level
detailed log, Chinese brief log, and English brief log.
Detailed log
Low power
consumption
Low power consumption, balanced, and high
performance. Only some models support the low
power mode.
Low power
consumption
Because DTU will generate real-time logs in debug mode , turn off this feature, the device will
run better.
4.8 InHand Device Manager (DM) platform
Table 4-7 Setting platform parameters
Parameters
Description
Default
SN
Set a 15-bit character string for the network
management platform to identify the device.
It is defined when manufacture, cannot be modified.
Empty
DM mode
Only SMS, SMS + IP, or disabled.
Only SMS
White List
The trusted list for accessing DTU, the DTU will interact
with white list phone number by SMS.
If the list is empty, it will receive the SMS of anyone.
Empty
DM ID
Enter the device ID used by the platform to identify the
device.
0
DM address
IP address 、Doamin name and port number for DM
0.0.0.0/g.inhandnet
works.com/
20003
Heart beat
interval
Set the heartbeat interval between the DTU and the
platform. The value ranges from 30 to 600 seconds.
120
Update
interval
Set the update interval about DTU state information
between the DTU and the platform. The value ranges
from 1 to 65535 seconds.
3600