User manual
IDRS-6000S-HE Series PC Based DVRs user Manual
42
[Sensor Type] Select NC or NO alarm type.
[Alarm Write log] Select write alarm log or not.
[Alarm Action After It Times-Out] Select system alarm linkage mode when an alarm
stops. “Stop Immediately” means the system stop alarm immediately after the alarm
driver stops an alarm. “Do Not Stop” means the system don’t stop alarm after the alarm
driver stops an alarm. “Wait” means the system will stop alarm at your setting time after
the alarm driver stops an alarm.
[Sensor input] Add sensor to selected group.
[Start recording cameras] Set cameras that to be related to this sensor group. They will
start recording and connect remote network client automatically when there is an alarm.
The cameras just include the cameras of local board card; IP Cameras are not included.
For IP Camera, you should set it remotely in
IP Camera setup.
[Trigger Output Relays] Add alarm devices (alarm out port) to this group such as siren,
light. All connecting devices will send alarm message when there is an alarm.
Schedule Setup (Example for below figure)
1. Check Alarm (Red): DVR System responds with sensor during this time. (00:30
to 12:00 from Sun. to Sat.)
2. Not check (gray): DVR System not respond with sensor in this time.
Note:
If you set a camera in several groups, only the last setup is available.