IDRS IP Camera IE Client User Manual Content 1. FEATURES ........................................................................................................................................................ 3 2. PRODUCTS SHAPE ......................................................................................................................................... 4 3. IP SEARCH & SET ..........................................................................................................................
IDRS IP Camera IE Client User Manual 1. Features Camera 1/3" Sony Super HAD CCD Horizontal resolution 540/480/420 TV Lines Auto Day/Night Switch Auto electronic shutter and auto gain control IR LED: ¢5×36PCS IR distance: 30m Video Compression H.
IDRS IP Camera IE Client User Manual 2.
IDRS IP Camera IE Client User Manual 3. IP search & set In the network camera software packages, there is a "search software SADP of IP Camera" folder, including SADP software. SADP software is used to identify and configure all the cameras’ IP address and mask address in the LAN (must be in an open state). SADP software uses unique search activated equipment technology, when the user does not know or has forgotten network camera's IP address, can find it via SADP software.
IDRS IP Camera IE Client User Manual 4. IP Camera(or DVS) to IE connection & operation 4.1 First time installation with Plug-in When you want to connect to the network camera, only need to input the network camera's IP address in the IE Address bar, then click the "link" or the "Enter" button on the keyboard.
IDRS IP Camera IE Client User Manual Note: If no window displayed or no respond after clicking on the installation button, check whether there is third-party software (such as firewalls, YAHOO assistant, 3721, and other software) to restrict the installation, if there are restrictions from third-party software, please remove the restrictions, or temporarily close the third-party software or firewall.
IDRS IP Camera IE Client User Manual 4.2 Main interface The logon interface will be displayed automatically after installation of plug-in.
IDRS IP Camera IE Client User Manual 4.2.1 Operation introduction Device list, double-click : Connect to image; double-click again: disconnect to image Connect/disconnect image Snapshot Manual record Talkback (available to talk to web servant positively) PTZ control button: control pan / tilt/zoom/aperture, as well as position of presetting Notice: before control, preset control protocol/address code/bit rate etc.
IDRS IP Camera IE Client User Manual Adjust saturation, grayscale, contrast, brightness. Real-timely adjust eavesdropping volume. Restore default by pressing lower-right corner. Mouse-hovering appears hint 4.2.2 Playback interface operation Press into search interface, like picture: Play button provides play, stop, slow play, rapid play and frame play. Mouse-hovering appears hint During remote playback, support snapshot, instant store, adjust playback volume.
IDRS IP Camera IE Client User Manual Search criteria: time search or video type search Start to search Search result list displays all related video data, select and press “playback” 11 / 30
IDRS IP Camera IE Client User Manual 4.2.3 Log search interface operation Select related search type on the right, press “search” button and display all logs needed. Press button on the lower right corner and move logs to local computer. 4.3 Remote setting operation 4.3.1 Configure parameters of server Press “Server parameters” item (like below picture) involves Server Configuration Information, Network Configuration Information and Server Version Information.
IDRS IP Camera IE Client User Manual Server Configuration Information: Server name: max.32 characters or 16 Chinese characters. Device number: 1.5 or more new version number is max. 255; 1.4 version number is max. 100. Loop record: when HD space is full, press “yes” with continuing record and covering old file; press “no” with stopping record. Channel quantity, HD quantity, alarm-in quantity, alarm-out quantity, server type and serial-number of server can not be revised.
IDRS IP Camera IE Client User Manual Manage host IP & port number: IP address and port number of PC host of receiving alarm signal. HTTP port number: used when visiting server by web pattern. Physical address of server: PPPoE address can not be revised. Server version information: main-control version, HD version, encode version and front panel version can not be revised. Setting finishes and press “save”. Some parameters require restart server for taking effect, press “restart” button. 4.3.
IDRS IP Camera IE Client User Manual Main stream: main encode mode for device; record parameter for DVR Sub stream: mainly applied for network transmission, suitable in unfavorable network. Event parameter:when event trigger happens (e.g. Motion detection alarm, mask alarm, signal quantity alarm), record parameter switches from timing record parameter to event compression parameter; when event is over, event compression parameter switches back to timing record parameter. Event parameter is optional.
IDRS IP Camera IE Client User Manual Select timing record mode, set relevant period. If select 24-hours record, only can set record type. Setting finishes, press “OK” for saving then exits configuration interface. When configuration is unnecessary Note: If set up the record method mobile detection or alarm video, and we should set up the mobile detection and alarm deployment.
IDRS IP Camera IE Client User Manual draw a box in the region, after a good painting Release the left mouse button, they set up a regional. Mobile can be set up to detect a number of regions, video can be set up to cover 4 regions, can only block one area. Choose Sensitivity: mobile detection can choose to 7, respectively, on behalf of the slider left to right: "closed" and 0-5 sensitivity of seven options, the lowest sensitivity of 0, 5 the highest.
IDRS IP Camera IE Client User Manual Select video channel trigger: the trigger-channel video channel can be a can also be a number. Set up to deal with the alarm: the choice of channel output linkage approach, you can select one or more of the warning means. Finished the setup, click "OK.
IDRS IP Camera IE Client User Manual Finished the setup of Parameter, click "OK." If the parameters can take effect only by restart, please restart. 4.3.4 Alarm parameters setup Choose the “alarm parameters” in the following chart; we can set up the alarm quantity parameters and abnormal parameters in the interface.
IDRS IP Camera IE Client User Manual Alarm input process: Choose the process”, the police enter click "deployment time"; come into the report to the police deployed in time as the following chart: 20 / 30
IDRS IP Camera IE Client User Manual After setup the deployment time, click "OK" button to save and come out the configuration interface. If not need save the set up click the "Cancel" button and return to the police parameter configuration interface Click the alarm input “linkage", come into the alarm input “linkage" interface, as the following chart: After set up the deployment time, click "OK" button to save and come out the interface.
IDRS IP Camera IE Client User Manual We can mange the server in the interface. Including user names, passwords, we can added and the abolition of authority by check on the” authorization”. When users select the user's permission to view. If the user already exists, right-node when the user pop-up menu, select "modify" the user to manage. Select the "delete" to delete the user. Super users can not be deleted.
IDRS IP Camera IE Client User Manual You can remote upgrade the server and format the hard disk in the interface. Select the "remote upgrade", click "Browse", choose the upgraded files. Click the "upgrade" to start upgrading. Finished the upgrade, suggesting "success to upgrade the server and please restart it.
IDRS IP Camera IE Client User Manual 5. Specifications Models IDRS-IPCAM1-Q IDRS-IPCAM1-H Image Sensor 1/3″ SONY Super HAD CCD Horizontal Resolution 540TVL Efficiency Resolution PAL: 704×576, NTSC:704×480(H ×V) Electric Shutter PAL=1/50 -1/100,000 s, NTSC=1/60 -1/100,000 s Min. Illumination 0 Lux S/N Ratio > 48dB(AGC off) Gamma 0.45 Lens Connector CS Video Output 1Channel, BNC(1.0Vp-p, 75Ω) Back Compensation on Video Compression H.
IDRS IP Camera IE Client User Manual Models IDRS-IPCAM2-Q Image Sensor Horizontal Resolution Pixel IDRS-IPCAM2-H IDRS-IPCAM2-D 1/3″SONY Super HAD CCD 540TVL 480TVL PAL:752×582, NTSC:768×494(H ×V) 420TVL PAL: 500×582 NTSC: 510×492(H ×V) Electrical Shutter PAL=1/50 -1/100,000 s, NTSC=1/60 -1/100,000 s Min. Illumination 0 Lux S/N Ratio > 48dB(AGC off) Gamma 0.
IDRS IP Camera IE Client User Manual Model IDRS-IPCAM3-Q IDRS-IPCAM3-H Image Sensor 1/3″SONY SUPERHAD CCD Resolution 540TVL Pixel PAL:752×582, NTSC:768×494(H ×V) 480TVL IDRS-IPCAM3-D 420TVL PAL: 500×582 NTSC: 510×492(H ×V) Electric Shutter PAL=1/50 -1/100,000 s, NTSC=1/60 -1/100,000 s Min. Illumination 0 Lux S/N Ratio > 48dB(AGC off) Gamma 0.
IDRS IP Camera IE Client User Manual Models IDRS-IPDOME3-H IDRS-IPDOME3-X IDRS-IPDOME3-W Camera Image Sensor 1/4″SONY CCD Image Sensor Effective Pixels PAL:752×582 NTSC:768 x 494(H x v) Horizontal 480TV lines 480TV lines 540TV lines Manual/ Auto (IR Cut Manual/ Auto (IR Cut Removable Filter) Removable Filter) 0.002Lux Color:0.4 Lux Resolution Day/Nigh Function Manual/ Auto Min. Illumination 0.01Lux B/W:0.001 Lux Digital Slow Shutter: 0.
IDRS IP Camera IE Client User Manual General Operating Temperature -30~65˚C Relative Humidity 0 to 95% RH (Non condensing) Power Supply AC24V Power Consumption 60Hz/50Hz 70W Protection Grade IP66 Weight 3.
IDRS IP Camera IE Client User Manual Model IDRS401D Video Compression H.264 Compression Resolution D1,DCIF,2CIF,CIF,QCIF Video Input Video Signal Frame Rate 1 BNC (Electrical Level: 1.
IDRS IP Camera IE Client User Manual Model IDRS401A Video Compression H.264 IDRS402A IDRS404A 2 4 Compression Resolution CIF,QCIF Video Input Video Signal Frame Rate 1 BNC (Electrical Level: 1.