Ribbon Tabs
3.
The download dialog opens and all panels connected in the network are
listed with information about IP address and panel type. Select the panel to
download to in the list.
4.
Check that the IP address is correct and click Download.
a. Optional: Click the “Include compressed project”checkboxtocompress
the project and save it as a ZIP file.
b. Optional: Click the “Password protected”checkboxandentera
password to protect the ZIP file.
c. Optional: Click the “Copy downloaded project to Memory card”check
box to enable SD-card backup of operator panel project and settings.
The panel responds to a download request by stopping any current project.
The panel displays that it is ready for project download. When the download is
completed, the new project automatically starts r unning.
The project folder is located at the following path. Only for PC targets!
%public%\Documents\Beijer Electronics AB\iX Developer Runtime\Project.
ThepanelsettingscanbecontrolledfromtheServicemenuinthepanel.
Note:
ItisnecessarytoopenTCPport9999andUDPport9999inthefirewallf
ortheruntime
PCapplication.
Note:
Donotattempttousethe Download commandifaprojectopenedwiththe.exe file is
open. Thismightfailtoclosetheprojectandthetransferwillnotbecompleted.
Note:
IfChineseorKoreanlanguagesaretobeusedintheoperatorpanel,thenfirewalls
inWindowsmustbecon figuredtoallowTransferClient.exefullaccessonallports,
otherwiseprojecttransfermightfail.
Relatedinformation
ServiceMenu
Starting aniXRuntime project ona PC
DownloadingaProject to anoperatorpaneloraPCwithan
iXRuntimeinstallationUsingFTP
A project can be loade
d to the panel via FTP. To be able to load a project remotely
an external storage
device (SD card or USB stick) must be attached, and a
configuration file
named ProjectCopy.config must be present in the root directory
of the storage de
vice.
Set up the configuration file as follows. Use # for parameters to be ignored.
BeijerElectronics, MAEN831P