5.6.20LAU_CONFIG_SETDEFAULTBRIGHTNESS
(0x01A6)
Default Brightness
A default brightness can be stored for the Beijer Electronics RBCs. This brightness is
used in two cases:
1. When both buttons (brighter and darker) on the front unit are pressed for about
1 second.
2. When the device is turned on and the startup brightness mode is set to default
brightness
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Note:
The changes made by this command will become active immediately.
0 1 2 3 4 5 6 7...9 10
0x07 ADR 0x4C 0x41 0x55 0x03 ICHKH 0x01 0xA6 Param ICHKD
Param
Value: 0 ... 255
Type: Byte
Length: 1
Description: Sets the default brightness
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0 ... 255
Type: Byte
Length: 1
Description: Returns the default brightness