38 Beijer Electronics, MAEN993
5.6.14LAU_CONFIG_SETDILMODE (0x018E)
DIL Switch Mode
For a base configuration, Beijer Electronics RBCs are equipped with DIL (DIP)
switches, where the device address and the serial interface mode can be selected. Be-
sides this configuration option, Beijer Electronics RBCs allow full software configu-
ration, which is stored in an internal Flash memory. The software configuration also
includes device address and serial interface mode setting. The value set by this com-
mand decides if the device uses hardware settings selected with the DIL switches, or
if it uses software settings stored in internal memory.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Note:
The changes made by this command will become active only after a restart of the de-
vice. This avoids loosing the connection to the device during configuration.
0 1 2 3 4 5 6 7...9 10
0x07 ADR 0x4C 0x41 0x55 0x03 ICHKH 0x01 0x8E Param ICHKD
Param
Value: 0x00: Configure the device to use the DIL switch settings
0x01: Configure the device to use the software settings
Type: Byte
Length: 1
Description: Use the DIL switch settings or the software settings
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0x00: Configure the device to use the DIL switch settings
0x01: Configure the device to use the software settings
Type: Byte
Length: 1
Description: Indicates whether the device uses the DIL switch settings or
the software settings