Manual

Command Reference
36 Beijer Electronics, MAEN993
5.6.13LAU_CONFIG_GETKEYPRESSMODE
(0x012A)
Keypress Mode
The brightness of the Beijer Electronics RBCs can be configured adopt a determined
value if both dimmer keys are pressed for longer than one second. There are five key-
press modes:
Backlight turns to darkest possible value (off )
Backlight turns to the level of the last received SCOM BRT command
Backlight turns to the default brightness, which can be configured as well
Backlight turns to brightest possible value
Backlight does not change
Supported since Firmware Version
LAUER RBC: 0.0.0.2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x2A ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0x00: Brightness is set to darkest possible value (off)
0x01: Brightness is set to the value of the last received SCOM
BRT command
0x02: Brightness is set to default brightness value
0x03: Brightness is set to brightest possible value
0x04: Brightness does not change
Type: Byte
Length: 1
Description: Indicates current keypress mode