Manual
Command Reference
Beijer Electronics, MAEN993 31
5.6.9 LAU_CONFIG_GETSTARTUPBRIGHTNESSMODE
(0x0124)
Startup Brightness Mode
The Beijer Electronics RBCs can be configured to start with different levels of bright-
ness. There are four modes for the backlight at startup:
• Backlight is off
• Backlight has the same level as before it was turned off
• Backlight starts with the default brightness, which can be configured as well
• Backlight is on with maximum brightness
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x24 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0x00: Device starts with minimum brightness (normally
backlight off)
0x01: Device starts with the same brightness as before it was
turned off
0x02: Device starts with default brightness
0x03: Device starts with maximum brightness
Type: Byte
Length: 1
Description: Indicates at which level the backlight is set at startup